Dell PowerEdge R815 Hardware Owner's Manual - Page 32
E1A14 SAS cable
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Code Text Causes E1813 Internal Dual The internal dual SD SD Module module card failed. Card # failed. Check SD card. E1814 Internal SD Module Card # writeprotected. Check SD card. The internal dual SD module card is writeprotected and cannot be used. E1815 Internal Dual The internal dual SD SD Module module bootable media is redundancy no longer redundant. lost. Check SD cards. E1A14 SAS cable A failure. Check connection. SAS cable A is missing or bad. E1A15 SAS cable B failure. Check connection. SAS cable B is missing or bad. E1A1D Control panel USB cable to the control USB cable not panel is missing or bad. detected. Check cable. Corrective Actions Reseat the internal dual SD module card. If the problem persists, see "Getting Help" on page 185. Change the write-protect switch setting on SD card. Reseat the internal dual SD module card. If the problem persists, see "Getting Help" on page 185. Reseat the cable. If the problem persists, replace the cable. If the problem persists, see "Getting Help" on page 185. Reseat the cable. If the problem persists, replace the cable. If the problem persists, see "Getting Help" on page 185 Reseat the cable. If the problem persists, replace the cable. If the problem persists, see "Getting Help" on page 185. 32 About Your System