Dell PowerEdge R815 Hardware Owner's Manual - Page 29
See Expansion Cards and, faulty. See Getting Help - review
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Code Text Causes Corrective Actions E1710 I/O channel check error. Review & clear SEL. The system BIOS reported an I/O channel check. Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. E1711 PCI parity error on Bus ## Device ## Function ##. The system BIOS reported a Remove and reseat the PCI parity error on a PCIe expansion cards. If component that resides in the problem persists, see PCI configuration space at "Troubleshooting bus ##, device ##, Expansion Cards" on function ##. page 166. PCI parity error on Slot #. Review & clear SEL. The system BIOS reported a Remove and reseat the PCI parity error on a PCIe expansion cards. If component that resides in the problem persists, see the specified slot. "Troubleshooting Expansion Cards" on page 166. E1712 PCI system error on Bus ## Device ## Function ##. The system BIOS reported a Remove and reseat the PCI system error on a PCIe expansion cards. If component that resides in the problem persists, see PCI configuration space at "Troubleshooting bus ##, device ##, Expansion Cards" on function ##. page 166. PCI system error on Slot #. Review & clear SEL. The system BIOS reported a Remove and reseat the PCI system error on a expansion-card riser that component that resides in provides the specified slot. the specified slot. See "Expansion Cards and Expansion-Card Risers" on page 107. If the problem persists, the riser card or system board is faulty. See "Getting Help" on page 185. About Your System 29