Check PSU and, Alert! Redundant
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Message Causes Corrective Actions Alert! Node Interleaving disabled! Memory configuration does not support Node Interleaving. The memory configuration has changed (for example, a memory module has failed) so that node interleaving cannot be supported. The system will run but without node interleaving. Ensure that the memory modules are installed in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 93. If the problem persists, see "Troubleshooting System Memory" on page 159. Alert! Power required exceeds PSU wattage. Check PSU and system configuration. Alert! Continuing system boot accepts the risk that system may power down without warning. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High Output power supplies to use the components. See "Power Supplies" on page 85. Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Redundant memory was enabled in the system setup program, but the current configuration does not support redundant memory. A memory module may be faulty. Check the memory modules for failure. See "Troubleshooting System Memory" on page 159. Reset the memory setting, if appropriate. See "Using the System Setup Program and UEFI Boot Manager" on page 53. About Your System 39