Dell PowerEdge R815 Hardware Owner's Manual - Page 50
Warning: The, General Memory Module
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Message Causes Corrective Actions HyperTransport error caused a system reset! Please check the system event log for details! A fatal system error occurred Check the SEL for and caused the system to information that is logged reboot. during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 151, for any faulty components specified in the SEL. Warning: Following faulty DIMMs are ignored: Faulty or improperly seated memory module(s). Check both DIMMs in the same channel for a possible fault. See "Troubleshooting Your System" on page 151. DIMM n1 n2 Total memory size is reduced. Warning: Following faulty DIMMs are disabled: Faulty or improperly seated memory module(s). Check both DIMMs in the same channel for a possible fault. See "Troubleshooting Your System" on page 151. DIMM n1 n2 Total memory size is reduced. Warning: The Invalid memory installed memory configuration. The system configuration is will run but with reduced not optimal. For functionality. more information on valid memory configurations, please see the system documentation on the technical support web site. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 93. If the problem persists, see "Troubleshooting System Memory" on page 159. NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals. 50 About Your System