E2013 BIOS unable, E2014 CMOS RAM
View all Dell PowerEdge R815 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Code Text Causes Corrective Actions E2010 Memory not detected. Inspect DIMMs. No memory detected in the system. Install memory or reseat the memory modules. See "Installing Memory Modules" on page 97 or "Troubleshooting System Memory" on page 159. E2011 Memory Memory detected, but is not See "Troubleshooting configuration configurable. Error detected System Memory" on failure. during memory page 159. Check DIMMs. configuration. E2012 Memory configured Memory configured, but is unusable. but unusable. Check DIMMs. See "Troubleshooting System Memory" on page 159. E2013 BIOS unable The system BIOS failed to to shadow copy its flash image into memory. Check memory. DIMMs. See "Troubleshooting System Memory" on page 159. E2014 CMOS RAM failure. Power cycle AC. CMOS failure. CMOS RAM Remove AC power to the not functioning properly. system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. E2015 DMA Controller failure. Power cycle AC. DMA controller failure. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. E2016 Interrupt Controller failure. Power cycle AC. Interrupt controller failure. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 185. About Your System 33