HP MSA 1040 HP MSA 1040 CLI Reference Guide (762782-001, March 2014) - Page 102
fail, help, history (Deprecated), causing data loss.
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
fail Description Forces the partner controller module to crash for a non-maskable interrupt. The command causes the crash by issuing an internal kill command to the Storage Controller in the partner controller module. This might be helpful to gather debug information that is only available via a crash dump. CAUTION: Do not use this command in a production system. Use only for testing. This command will interfere with the operation of volumes in vdisks owned by the failed controller, potentially causing data loss. Syntax fail controller a|b Parameters controller a|b Specifies whether to kill controller A or B. You cannot kill the controller on which the command is issued. Example From controller A, fail controller B: # fail controller b Success: Command completed successfully. - Successfully failed (killed) Storage Controller B. (2013-08-08 16:29:50) See also • unfail controller help See "Viewing help" (page 21). history (Deprecated) This command has no effect. For information about using the command history, see "Command completion, editing, and history" (page 21). 102