HP MSA 1040 HP MSA 1040 CLI Reference Guide (762782-001, March 2014) - Page 115
rescan, Description, Syntax, Example
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
rescan Description This command forces rediscovery of disks and enclosures in the storage system. If both Storage Controllers are online and able to communicate with both expansion modules in each connected enclosure, this command rebuilds the internal SAS layout information, reassigns enclosure IDs based on controller A's enclosure cabling order, and ensures that the enclosures are displayed in the proper order. A manual rescan temporarily pauses all I/O processes, then resumes normal operation. It can take up to two minutes for the enclosure IDs to be corrected. A manual rescan may be needed after system power-up to display enclosures in the proper order. Whenever you replace a drive chassis or controller chassis, perform a manual rescan to force fresh discovery of all drive enclosures connected to the controller enclosure. A manual rescan is not needed after inserting or removing disks; the controllers automatically detect these changes. When disks are inserted they are detected after a short delay, which allows the disks to spin up Syntax rescan Example Scan for device changes and re-evaluate enclosure IDs: # rescan Success: Command completed successfully. (2012-01-21 12:20:57) rescan 115