HP MSA 1040 HP MSA 1040 CLI Reference Guide (762782-001, March 2014) - Page 233
Disabled, Enabled, Reason, Error count interrupts, Phy control, Not ready, Drive removed
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 233 highlights
Disabled • Enabled: PHY is enabled. • Disabled: PHY is disabled. Reason • Blank if Elem Status is OK. • Error count interrupts: PHY disabled because of error-count interrupts. • Phy control: PHY disabled by a SES control page as a result of action by a Storage Controller or user. • Not ready: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O module is not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem exists such as a broken connector. • Drive removed: PHY disabled because drive slot is empty. • Unused - disabled by default: PHY is disabled by default because it is not used. • Excessive Phy changes: PHY is disabled because of excessive PHY change counts. Example Show expander status for a 2U24 system: # show expander-status Encl Ctlr Phy Type Status Elem Status Disabled Reason 1 A 0 Drive Enabled - Healthy OK Enabled 1 A 1 Drive Disabled OK Disabled Drive removed ... Encl Ctlr Phy Type Status Elem Status Disabled Reason 1 B 0 Drive Enabled - Healthy OK Enabled 1 B 1 Drive Disabled OK Disabled Drive removed ... Success: Command completed successfully. (2013-07-31 15:02:13) Basetypes • sas-status-controller-a • status See also • clear expander-status • set expander-fault-isolation • set expander-phy show expander-status 233