vdisk-statistics, This basetype is used by, when the, parameter is omitted.
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 480 highlights
vdisk-statistics This basetype is used by show vdisk-statistics when the historical parameter is omitted. Table 87 vdisk-statistics properties Name Type Description name serial-number bytes-persecond bytes-persecond-numeric iops string string string uint32 Vdisk name. Vdisk serial number. Data transfer rate calculated over the interval since these statistics were last requested or reset. This value will be zero if it has not been requested or reset since a controller restart. Unformatted bytes-per-second value. uint32 Input/output operations per second, calculated over the interval since these statistics were last requested or reset. This value will be zero if it has not been requested or reset since a controller restart. number-of-reads uint64 Number of read operations since these statistics were last reset or since the controller was restarted. number-ofwrites data-read uint64 string Number of write operations since these statistics were last reset or since the controller was restarted. Amount of data read since these statistics were last reset or since the controller was restarted. data-readnumeric data-written uint32 Unformatted data-read value. string Amount of data written since these statistics were last reset or since the controller was restarted. data-writtennumeric avg-rsp-time uint32 Unformatted data-written value. uint32 Average response time in microseconds for read and write operations, calculated over the interval since these statistics were last requested or reset. avg-read-rsptime avg-write-rsptime reset-time uint32 uint32 string Average response time in microseconds for all read operations, calculated over the interval since these statistics were last requested or reset. Average response time in microseconds for all write operations, calculated over the interval since these statistics were last requested or reset. Date and time, in the format year-month-day hour:minutes:seconds, when these statistics were last reset, either by a user or by a controller restart. reset-timenumeric start-sampletime start-sampletime-numeric stop-sampletime stop-sampletime-numeric uint32 Unformatted reset-time value. string uint32 Date and time, in the format year-month-day hour:minutes:seconds, when sampling started for the iops and bytes-per-second values. Unformatted start-sample-time value. string uint32 Date and time, in the format year-month-day hour:minutes:seconds, when sampling stopped for the iops and bytes-per-second values. Unformatted stop-sample-time value. 480 XML API basetype properties