Lenovo NetVista X40 Quick Reference for NetVista 2179 and 6643 systems (Dutch) - Page 100

Microprocessor in socket id, Reseat

Page 100 highlights

Code Function 089 Microprocessor Result Failed Text message Invalid microprocessor in slot xyz or BIOS setup problem (where xyzidentifies the microprocessor that is causing the error message) Processor in socket id xyz is installed but not functioning (where xyz identifies the microprocessor that is causing the error message) Microprocessor in socket id xyz (where xyz identifies the microprocessor that is causing the error message) Processor in socket id xyz is defective (where xyz identifies the microprocessor that is causing the error message) Test setup error: Application microprocessor not installed or BIOS setup problem Action 1. Check the system error log for the related error messages. 2. If your system does not have the latest level BIOS installed, update the BIOS. 3. If the problem remains, replace the xyz microprocessor and run the test again. If the problem persists, call for service. 1. Reseat the microprocessor. 2. If the problem remains, replace the microprocessor. If the problem persists, call for service. Replace the microprocessor. If the problem persists, call for service. 1. Verify that the Application microprocessor is installed and seated correctly. 2. If your system does not have the latest level BIOS installed, update the BIOS. 3. If the problem remains, replace the Application microprocessor and run the test again. If the problem persists, call for service. 84 IBM® IntelliStation® E Pro: User's Guide IntelliStation E Pro Types 6836, 6846

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

Code
Function
Result
Text message
Action
089
Microprocessor
Failed
Invalid microprocessor in slot
xyz
or BIOS setup
problem
(where
xyz
identifies the microprocessor that is
causing the error message)
1.
Check the system
error log for the
related error
messages.
2.
If your system does
not have the latest
level BIOS installed,
update the BIOS.
3.
If the problem
remains, replace the
xyz
microprocessor
and run the test
again.
If the problem persists,
call for service.
Processor in socket id
xyz
is installed but not
functioning
(where
xyz
identifies the microprocessor that is
causing the error message)
Microprocessor in socket id
xyz
(where
xyz
identifies the microprocessor that is
causing the error message)
1.
Reseat the
microprocessor.
2.
If the problem
remains, replace the
microprocessor.
If the problem persists,
call for service.
Processor in socket id
xyz
is defective
(where
xyz
identifies the microprocessor that is
causing the error message)
Replace the
microprocessor.
If the problem persists,
call for service.
Test setup error: Application microprocessor not
installed or BIOS setup problem
1.
Verify that the
Application
microprocessor is
installed and seated
correctly.
2.
If your system does
not have the latest
level BIOS installed,
update the BIOS.
3.
If the problem
remains, replace the
Application
microprocessor and
run the test again.
If the problem persists,
call for service.
84