Lenovo NetVista X40 Quick Reference for NetVista 2179 and 6643 systems (Dutch) - Page 101

Test setup error: Corrupt BIOS in ROM, information

Page 101 highlights

Code Function Microprocessor Result Failed 175 System thermal Failed 180 Status display Failed 201 System memory Failed Text message Action VRM corresponding to microprocessor in socket xyzis defective (where xyz identifies the microprocessor whose VRM is causing the error message) Replace the VRM. If the problem remains, call for service. VRM corresponding to microprocessor in socket id Install a VRM. xyz is not installed If the problem persists, (where xyzidentifies the microprocessor whose call for service. VRM is causing the error message) Fan # n (where n is the number of the failing fan) Replace the indicated fan. Temperature sensed on processor board is out of Call for service. range Any failure message Call for service. DIMMs in location DIMM n (where nis the number of the socket that contains the failing DIMM) 1. Reseat the failing DIMM. 2. If the problem remains, replace the DIMM. If the problem persists, call for service. Test setup error: Corrupt BIOS in ROM Test setup error: Corrupt DMI BIOS, information in BIOS is not as expected If your system does not have the latest level BIOS installed, update the BIOS to the latest level. If the problem persists, call for service. Chapter 6. Solving problems 85

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

Code
Function
Result
Text message
Action
Microprocessor
Failed
VRM corresponding to microprocessor in socket
xyz
is defective
(where
xyz
identifies the microprocessor whose
VRM is causing the error message)
Replace the VRM.
If the problem remains,
call for service.
VRM corresponding to microprocessor in socket id
xyz
is not installed
(where
xyz
identifies the microprocessor whose
VRM is causing the error message)
Install a VRM.
If the problem persists,
call for service.
175
System thermal
Failed
Fan #
n
(where
n
is the number of the failing fan)
Replace the indicated
fan.
Temperature sensed on processor board is out of
range
Call for service.
180
Status display
Failed
Any failure message
Call for service.
201
System memory
Failed
DIMMs in location DIMM
n
(where
n
is the number of the socket that contains
the failing DIMM)
1.
Reseat the failing
DIMM.
2.
If the problem
remains, replace the
DIMM.
If the problem
persists, call for
service.
Test setup error: Corrupt BIOS in ROM
If your system does not
have the latest level
BIOS installed, update
the BIOS to the latest
level.
If the problem persists,
call for service.
Test setup error: Corrupt DMI BIOS, information
in BIOS is not as expected
Chapter 6. Solving problems
85