Xerox 8500DN Service Manual - Page 142
Strip Solenoid, Purge Vent Solenoid, Drum Heater Relay
![]() |
UPC - 095205022063
View all Xerox 8500DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 142 highlights
General Troubleshooting 4-12 Gathers data on the performance of the stripper solenoid coil and plunger. Strip Solenoid R# Definition Typical Value (8400) 0 Peak Power (watts) 8.0 to 15 1 Average Power (watts) 8.0 to 15 Typical Value (8500/ 8550/8560) Actions 22 to 27 Reports the max power value. 20.0 to 30.0 Reports the average power. Gathers data on the performance of the purge vent solenoid coil. Purge Vent Solenoid R# Definition Typical Value (8400) Typical Value (8500/ 8550/8560) Actions 0 Peak Power (watts) 0.5 to 1.2 -.12 to 1.2 Reports the max power value. 1 Average Power (watts) 0.4 to 1.2 .15 to 1.2 Reports the average power. Gathers data on the performance of the drum heater dual relay assembly by energizing each relay for a short time and capturing the resulting power draw. Drum Heater Relay R# Definition Typical Value (8400) 0 220 V Coil Peak Power (watts) 1 220 V Coil Average Power (watts) 2 220 V Coil Min Power (watts) 3 220 V Coil Peak Power Time (sec) 4 220 V Coil Initial Average Power (watts) 5 110 V Coil Peak Power (watts) Typical Value (8500/ 8550/8560) Actions .2 to 1.2 Reports the max power value. .2 to 1.2 Reports the average power. .2 to .45 .2 to .45 Reports the min power following power off. Reports time after solenoid power on that the peak power occurred. Reports the average power following power on. .2 to 1.0 Reports the max power value. Phaser 8400/8500/8550/8560 Color Printer Service Manual
![](/manual_guide/products/xerox-8500dn-service-manual-25944ce/142.png)