ZyXEL P-663HN-51 User Guide - Page 183
Configuring Log Settings
View all ZyXEL P-663HN-51 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 183 highlights
Chapter 21 Logs 21.4 Configuring Log Settings Click Management > System Log > Configure System Log to display the following screen. Use this screen to configure the level of events to log and where to send logs. Figure 92 Management > System Log > Configure System Log The following table describes the fields in this screen. Table 64 Management > System Log > Configure System Log LABEL DESCRIPTION Log This controls whether or not the ZyXEL Device logs events. Log Level Select the lowest level of events that you want the ZyXEL Device to log. The ZyXEL Device logs all events with that severity level or higher. Display Level Select the lowest level of events that you want the ZyXEL Device to display. The ZyXEL Device displays events with that severity level or higher. Mode Select Local to only record events in the ZyXEL Device's memory. Select Remote to send events to a remote syslog server. Select Both to record events in the ZyXEL Device's memory and send them to a remote syslog server. Server IP Address Enter the server name or IP address of the syslog server that will log the selected categories of logs. Server UDP Port Enter the UDP port number the ZyXEL Device is to use when sending syslog events to the syslog server. Save/Apply Click this button to save the changes and have the ZyXEL Device start using them. P-663HN-51 User's Guide 183