Icom IC-2820H Instruction Manual - Page 155
Fuse replacement
View all Icom IC-2820H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 155 highlights
MAINTENANCE 17 PROBLEM POSSIBLE CAUSE SOLUTION Some memory channels • The memory channel number has not yet been • Select the channel via the microphone keypad to cannot be selected via the programmed. check whether the channel has been programmed tuning dial. or not. REF. - Scan does not operate. • The squelch is open. • Set the squelch to the threshold point. p. 22 • Only 1 memory channel is programmed or other • Program other memory channels or cancel the pgs. 62, channels are set as skip channels. memory skip function in the desired channels. 63, 79 • Priority watch is activated. • Cancel the watch. p. 81 Transmission is automati- • Time-out timer is activated. cally cut off. • Set the timer to OFF. p. 101 Transmission continues • One-touch PTT function is activated. even when the PTT is released. • Turn the function OFF. p. 26 During tone squelch opera- • Transmitter's microphone gain is too high. tion, the received audio breaks off at the other station. • Select low microphone sensitivity in set mode. • Turn the ALC function ON in set mode. p. 102 p. 102 The function display shows • The CPU is malfunctioning. erroneous information. • Reset the CPU. p. 116 ■ Fuse replacement If the fuse blows or the transceiver stops functioning, find the source of the problem if possible, and replace the blown fuse with a new, properly rated one (FGB 20 A) as shown at right. 20 A fuse 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 134