Icom IC-2820H Instruction Manual - Page 96

Scan start/stop

Page 96 highlights

8 SCAN OPERATION ■ Scan start/stop D Preparation Scan resume condition (p. 78); program the scan edges (pgs. 76, 77); program 2 or more memory channels (pgs. 62, 63); set skip settings, if desired (p. 79). D Operation qSelect VFO mode for full/programmed scan with [V/MHz•SCAN]; or memory mode for memory scan with [M/CALL•MW] in the desired band (Left or Right). • Select the desired bank with the same band's [MAIN•BAND] for bank scan. w Push and hold the same band's [V/MHz•SCAN] for 1 sec. eRotate the same band's [DIAL] to select the scan type from ALL and programmed scan (PROG 0 to PROG 9), if VFO is selected in step q. rPush the same band's [V/MHz•SCAN] momentarily to start the scan. • To change the scanning direction, rotate the same band's [DIAL]. • The memory channel readout blinks the scan type as follows: • During full scan • During programmed scan tTo stop the scan, push the same band's [V/MHz•SCAN]. z Push [VFO/LOCK] to select VFO mode for SCAN 2 full/programmed scan; push [MR/CALL] to select memory mode for memory scan, in the main band. • Push [FUNC] then [MONI 1(BANK)] to select a bank for bank scan. x Push [SCAN 2(T-SCAN)]. c Push [Y] or [Z] to select the ALL and pro- grammed scan (PROG 0 to PROG 9), if VFO is se- lected in step z. v Push [SCAN 2(T-SCAN)] again to start the scan. • Push [Y] or [Z] for 1 sec. also starts the scan. b To stop the scan push [SCAN 2(T-SCAN)] or [CLR A(MW)]. • During memory scan • During bank scan Rotate [DIAL] to select "ALL" (full) or programmed scan (P1 to P9) in sequence. 75 Indicates scan edge channels. • P1 stands for 1A/1B Indicates bank initial.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

75
8
SCAN OPERATION
Scan start/stop
D
Preparation
Scan resume condition
(p. 78)
; program the scan edges
(pgs. 76, 77)
; program 2 or more memory channels
(pgs. 62,
63)
; set skip settings, if desired
(p. 79)
.
D
Operation
q
Select VFO mode for full/programmed scan with
[V/MHz•SCAN]
; or memory mode for memory scan with
[M/CALL•MW]
in the desired band
(Left or Right)
.
• Select the desired bank with the same band’s
[MAIN•BAND]
for
bank scan.
w
Push and hold the same band’s
[V/MHz•SCAN]
for 1 sec.
e
Rotate the same band’s
[DIAL]
to select the scan type
from ALL and programmed scan
(PROG 0 to PROG 9)
, if
VFO is selected in step
q
.
r
Push the same band’s
[V/MHz•SCAN]
momentarily to start
the scan.
To change the scanning direction, rotate the same band’s
[DIAL]
.
• The memory channel readout blinks the scan type as follows:
t
To stop the scan, push the same band’s
[V/MHz•SCAN]
.
z
Push [VFO/LOCK] to select VFO mode for
full/programmed scan; push [MR/CALL] to select
memory mode for memory scan, in the main
band.
• Push [FUNC] then [
MONI
1(BANK)] to select a bank
for bank scan.
x
Push [
SCAN
2(T-SCAN)].
c
Push [
Y
] or [
Z
] to select the ALL and pro-
grammed scan
(PROG 0 to PROG 9)
, if VFO is se-
lected in step
z
.
v
Push [
SCAN
2(T-SCAN)] again to start the scan.
• Push [
Y
] or [
Z
] for 1 sec. also starts the scan.
b
To stop the scan push [
SCAN
2(T-SCAN)] or
[
CLR
A(MW)].
SCAN
2
• During full scan
• During programmed scan
• During memory scan
• During bank scan
Indicates scan edge channels.
• P1 stands for 1A/1B
Indicates bank initial.
Rotate [DIAL] to select “ALL”
(full) or programmed scan (P1