Appendix E Appendix E Troubleshooting Guide NOTE: The following is a checklist of the common problems encountered during installation. For failures that occur during operation, refer to the failure recovery procedure in the "Disk Failure Management" section. PROBLEM CHECK Text RAID Manager indicates a SCSI channel failure detected upon start-up (SCSI cables connected). 1. Check ID numbers (must be unique for each device on the same SCSI channel). 2. Make sure terminators are properly installed. 3. Check the voltage output of the power supply. Initialization failure 1. Check ID numbers (must be unique for each device on the same SCSI channel). 2. Make sure terminators are properly installed. Cannot detect SCSI drive 1. Check drive power connections. 2. Check drive SCSI cable connections. 3. Check ID numbers (must be unique for each device on the same SCSI channel). Parity error detected 1. DRAM SIMM should be replaced. Logical drive failure detected during boot-up 1. Check proper installation or connection of the drives (use the "View SCSI drives" function to help locate the problem). ASUS PCI-DA2100/PCI-DA2200 User's Manual 189