Asus PCI-DA2100 User Manual - Page 27
Dynamic Logical Drive Expansion
View all Asus PCI-DA2100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
3 SAF-TE Support UPS Failure Signal Input Text RAID Manager error alert PCI-to-SCSI SAF-TE Chipset Cooling Fan Failure Signal Input System with RAID controller installed GUI RAID Manager error alert Power Supply Failure Signal Input Drive Status Indicators Temperature Alert Signal Input • The SAF-TE chipset connects to the drive channel of the controller together with the other SCSI drives. 3.5.8 Periodic Auto-Detect Failure Drive Swap Check Time The "Drive-Swap Check Time" is the interval at which the controller checks to see whether a failed drive has been swapped. When a logical drive's member drive fails, the controller will detect the failed drive (at the selected time interval). Once the failed drive has been swapped with a drive that has adequate capacity to rebuild the logical drive, the rebuild will begin automatically. The default setting is "Disabled," meaning that that the controller will not Auto-Detect the swap of a failed drive. To enable this feature, select a time interval. 3.6 Dynamic Logical Drive Expansion 3.6.1 What Is It and How Does It Work? Before Dynamic Logical Drive Expansion, increasing the capacity of a RAID system using traditional methods meant backing up, recreating and then restoring. Dynamic Logical Drive Expansion allows ASUS PCI-DA2100/PCI-DA2200 User's Manual 27