Asus PCI-DA2100 User Manual - Page 282
temperature, fan rotation, power supply failure or the UPS power
View all Asus PCI-DA2100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 282 highlights
ASUS GUI RAID Manager: Basic Operations at Startup Fault Bus is a proprietary enclosure management interface. It will warn the user if a dangerous situation occurs within the RAID system. Fault Bus gathers the failure signals from the cooling fans, redundant power supply, enclosure temperature sensor and UPS device. In the GUI RAID Manager, it reports this failure information to the user by displaying a red "X" on whichever device has failed. Fault Bus only collects the failure signals; it does not detect the temperature, fan rotation, power supply failure or the UPS power failure. Either a user-designed circuit or a 3rd-party circuit is necessary for Fault Bus. This circuit must be configured properly for Fault Bus to work. To configure the user-designed/3rd-party circuit, double-click on the Fault Bus icon with your mouse. 3.6 Working with Windows 3-27