Brother International HL-2400C Service Manual - Page 271
Is DCN1 of IOD1 properly connected with 11CN of MCTL PCB ?
View all Brother International HL-2400C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 271 highlights
VIII-26 Error Code Concerned Part E5 Transfer Solenoid Check the connection of the transfer solenoid connector. YES Is ECN8 of IOD2 properly connected with a connector of the solenoid ? NO Is ECN2 of IOD2 properly connected with DCN9 of IOD1 ? Is DCN1 of IOD1 properly connected with 11CN of MCTL PCB ? YES Check the voltage(TRSLON-N/P) Is the voltage between ECN8-4 and ECN2-8 of IOD2 a trailing edge ? YES NO Is the voltage between ECN2-3 and 12 of IOD2 a trailing edge ? YES Is the voltage between ECN2-31 and 1 of IOD1 a rising edge ? YES NO Is E5 error cleared ? NO YES Finished. Connect them properly. Is E5 error cleared ? NO YES Finished. Replace the transfer solenoid. Replace the IOD2 PCB. Replace the IOD1 PCB. Replace the MCTL PCB. MCTL IOD1 IOD2 11CN DCN1 DCN9 ECN2 1 SGND 1 31 TRSLON-P 31 3 TRSLON-N 3 8 PGND 8 12 SGND 12 ECN8 1 +24V-1 Transfer Solenoid 4 TRSLON-N TRSL