Brother International HL-2400C Service Manual - Page 312
Re-enter the original EACH IMAGE IY, IM, IC, IK values in EACH IMAGE SET
View all Brother International HL-2400C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 312 highlights
iii) Check that the value of NEXT CARE is reset correctly. (i.e.) NC8 = 39,684P iv) Reset the LIFE PERIOD counter in FACTORY MODE to 60,100. 7) Re-enter the 120K KIT (NC9) value as follows; i) Enter the value of NC9 - LP9 into the TOTAL PAGE counter. (i.e.) NC9 - LP9 = 120,000 - 120,000 = 0 Enter the value '0' into the TOTAL PAGE counter. ii) Perform CLEAR CARE 9. (Refer to '36 CLEAR CARE' in page V-24 of Chapter V.) iii) Check that the value of NEXT CARE is reset correctly. (i.e.) NC9 = 120,000P 8) Re-enter the original TOTAL PAGE (T) value in TOTAL PAGE SET in FACTORY MODE. (i.e.) T = 412P 9) Re-enter the original EACH IMAGE (IY, IM, IC, IK) values in EACH IMAGE SET in FACTORY MODE. (i.e.) (IY)=348P, (IM)=353P, (IC)=365P, (IK)=439P 10) Ensure that the values in the LIFE PERIOD SET counters in FACTORY MODE are correct. (i.e.) FC ROLL (LP2)=12,000P BL UNIT (LP7)=50,000P FU UNIT (LP8)=60,100P 120K KIT (LP9)=120,000P 11) Completed. A-10