4. Remove the service-station cap by pressing on the four lateral fixings (two each side), and pulling up. 5. Make a visual check of the service-station cap. If you see that it is damaged or deformed, discard it and fetch a new one. 6. Put back the old service-station cap or install a new one, as required. Correctly orient the cap in the capping station. NOTE: The cap is asymmetrical. 7. Locate the pins under the cap assembly and align them with the holes. IMPORTANT: Do not tilt the cap assembly. 250 Chapter 11 Hardware maintenance
![](/manual_guide/products/hewlettpackard-latex-2700-user-guide-72cb20f/257.png)
4.
Remove the service-station cap by pressing on the four lateral fixings (two each side), and pulling up.
5.
Make a visual check of the service-station cap. If you see that it is damaged or deformed, discard it and
fetch a new one.
6.
Put back the old service-station cap or install a new one, as required.
Correctly orient the cap in the capping station.
NOTE:
The cap is asymmetrical.
7.
Locate the pins under the cap assembly and align them with the holes.
IMPORTANT:
Do not tilt the cap assembly.