Yamaha 01V96i Reference Manual - Page 108

To receive bulk data, press the DISPLAY, sor to the TRANSMIT button, then press - 01v96vcm

Page 108 highlights

108 MIDI 5. If necessary, move the cursor to the parame- ter box next to the selected button, then rotate the Parameter wheel or press the [INC]/[DEC] buttons to select the desired bulk dump data. Tip: If you selected [ALL] in the parameter box, all data selected by the corresponding button is transmitted as bulk dump data. 6. To start transmitting bulk data, move the cur- sor to the TRANSMIT button, then press [ENTER]. Bulk Dump is executed. During the operation, the Bulk Dump window appears, indicating the current bulk dump status. To abort the bulk dump operation, move the cursor to the CANCEL button in the window, then press [ENTER]. Tip: To transmit bulk dump request messages, move the cursor to the REQUEST button, then press [ENTER]. If you set up the 01V96i so that it will transmit and receive MIDI messages to and from another 01V96i, the other 01V96i will respond to the bulk dump request and transmit the bulk dump data to the 01V96i you are operating. 7. To receive bulk data, press the DISPLAY ACCESS [MIDI] button again to display the MIDI | Setup page, then turn on the Rx ON/OFF button in the BULK row. Now, when the 01V96i receives bulk data, the corresponding internal data is updated. Note: Bulk data can be transmitted and received between the 01V96i and the 01V96V2 / 01V96VCM. Compatibility depends on the type of data, as follows. Data that can be transmitted and received between the 01V96i and the 01V96V2 / 01V96VCM in either direction SCENE MEM: EQ LIBRARY: GATE LIBRARY: COMP LIBRARY: CHANNEL LIBRARY: EFFECT LIBRARY: BANK: SETUP MEMORY: PGM TABLE: CTL TABLE: Data that can be only be transmitted by the 01V96V2 / 01V96VCM and received by the 01V96i (and not in the other direction) INPUT PATCH LIBRARY: OUTPUT PATCH LIBRARY: 01V96i-Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

108
MIDI
01V96i—Reference Manual
5.
If necessary, move the cursor to the parame-
ter box next to the selected button, then
rotate the Parameter wheel or press the
[INC]/[DEC] buttons to select the desired
bulk dump data.
6.
To start transmitting bulk data, move the cur-
sor to the TRANSMIT button, then press
[ENTER].
Bulk Dump is executed. During the operation, the Bulk
Dump window appears, indicating the current bulk
dump status. To abort the bulk dump operation, move the
cursor to the CANCEL button in the window, then press
[ENTER].
7.
To receive bulk data, press the DISPLAY
ACCESS [MIDI] button again to display the
MIDI | Setup page, then turn on the Rx
ON/OFF button in the BULK row.
Now, when the 01V96i receives bulk data, the corre-
sponding internal data is updated.
Tip:
If you selected [ALL] in the parameter box, all data
selected by the corresponding button is transmitted as bulk
dump data.
Tip:
To transmit bulk dump request messages, move the cur-
sor to the REQUEST button, then press [ENTER]. If you set
up the 01V96i so that it will transmit and receive MIDI mes-
sages to and from another 01V96i, the other 01V96i will
respond to the bulk dump request and transmit the bulk
dump data to the 01V96i you are operating.
Note:
Bulk data can be transmitted and received between the
01V96i and the 01V96V2 / 01V96VCM. Compatibility
depends on the type of data, as follows.
Data that can be transmitted and received between the
01V96i and the 01V96V2 / 01V96VCM in either direction
SCENE MEM:
EQ LIBRARY:
GATE LIBRARY:
COMP LIBRARY:
CHANNEL LIBRARY:
EFFECT LIBRARY:
BANK:
SETUP MEMORY:
PGM TABLE:
CTL TABLE:
Data that can be only be transmitted by the 01V96V2 /
01V96VCM and received by the 01V96i (and not in the other
direction)
INPUT PATCH LIBRARY:
OUTPUT PATCH LIBRARY: