Yamaha 01V96i Reference Manual - Page 111

Cascading Consoles, Patch | Cascade In appears. - digital console

Page 111 highlights

Other Functions Cascading Consoles 111 Cascading Consoles The 01V96i features a Cascade Bus that enables cascade connection. You can connect two 01V96is in cascade using the digital inputs and outputs, or the OMNI IN and OMNI OUT connectors. In this way, two consoles work just like one big console, integrating each unit's Buses 1-8, Aux Sends 1-8, Stereo Bus, and Solo Bus. The following functions are linked between two cascaded 01V96is via the MIDI IN and OUT ports. • Display page selection • Solo function • Fader Mode • Metering Position • Peak Hold On/Off • Meter Fast Fall on/off • Scene Store, Recall, and Title Edit Tip: • To link functions and parameters (excluding the Solo func- tion), turn on the Cascade COMM Link check box on the Setup | Prefer1 page (see page 109). • The Solo function is always linked regardless of the status of the Cascade COMM Link check box. The following paragraphs explain how to make a cascade connection using two 01V96is and the inputs and outputs of the digital I/O card installed in the slot of each 01V96i. 1. Install digital I/O cards into the slot on each of two 01V96is. 2. Connect two 01V96is as follows: • Connect the digital I/O card output on the transmitting 01V96i (slave) to the digital I/O card input on the receiving 01V96i (master). • Connect the ADAT IN connector on the master unit to the ADAT OUT connector on the slave unit. • Connect the MIDI IN port on the master unit to the MIDI OUT port on the slave unit using a MIDI cable. • Connect the MIDI OUT port on the master unit to the MIDI IN port on the slave unit using a MIDI cable. OUT IN MY8-AT etc. ADAT OUT SLOT connector MIDI IN/OUT connector MY8-AT etc. SLOT ADAT IN connector MIDI IN/OUT connector CH1-4 CH5-8 CH9-12 1 2 3 4 5 6 7 8 9 10 11 12 PHANTOM +48V 13 15 A A A A A A A A A A A A 14 B B B B B B B B B B B B INPUT (BAL) INSERT OUT IN (UNBAL) INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O L 16 R IN OUT 2TR -10dBV (UNBAL) PHONES CH15/16 2TR IN MONITOR 2TR IN PAD 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB +4 GAIN -26 +4 GAIN -26 0 LEVEL10 -16 -60 GAIN +4 GAIN -26 +4 GAIN -26 MONITOR OUT PEAK SIGNAL 13 PEAK 14 15 PEAK 16 SIGNAL SIGNAL 0 LEVEL10 PHONES DISPLAY ACCESS SCENE MEMORY SCENE DIO/SETUP MIDI UTILITY / INSERT/ PAN/ PAIR/ DELAY ROUTING GROUP PATCH DYNAMICS EQ EFFECT FADER MODE VIEW AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 AUX 8 HOME (METER) LAYER 1-16 17-32 MASTER REMOTE OVER 0 -3 -6 -9 -12 -15 -18 -24 -30 -36 -48 STEREO STORE DEC Q HIGH HIGH-MID FREQUENCY LOW-MID GAIN LOW ENTER RECALL SOLO CLEAR INC ST IN CH1-4 CH5-8 CH9-12 1 2 3 4 5 6 7 8 9 10 11 12 PHANTOM +48V 13 15 A A A A A A A A A A A A 14 B B B B B B B B B B B B INPUT (BAL) INSERT OUT IN (UNBAL) INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O INSERT I/O L 16 R IN OUT 2TR -10dBV (UNBAL) PHONES CH15/16 2TR IN MONITOR 2TR IN PAD 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB -16 -60 GAIN PEAK SIGNAL 20dB +4 GAIN -26 +4 GAIN -26 0 LEVEL10 -16 -60 GAIN +4 GAIN -26 +4 GAIN -26 MONITOR OUT PEAK SIGNAL 13 PEAK 14 15 PEAK 16 SIGNAL SIGNAL 0 LEVEL10 PHONES DISPLAY ACCESS SCENE MEMORY SCENE DIO/SETUP MIDI UTILITY / INSERT/ PAN/ PAIR/ DELAY ROUTING GROUP PATCH DYNAMICS EQ EFFECT FADER MODE VIEW AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7 AUX 8 HOME (METER) LAYER 1-16 17-32 MASTER REMOTE OVER 0 -3 -6 -9 -12 -15 -18 -24 -30 -36 -48 STEREO STORE DEC Q HIGH HIGH-MID FREQUENCY LOW-MID GAIN LOW ENTER RECALL SOLO CLEAR INC ST IN SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SEL SEL SEL SOLO SOLO ON ON ON ST IN 1 ST IN 2 SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SEL SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO SOLO ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SEL SEL SEL SOLO SOLO ON ON ON ST IN 1 ST IN 2 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 00 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 20 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 30 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 40 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 50 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 60 70 70 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 USER DEFINED KEYS 1 2 3 4 5 6 7 8 1 17 AUX 1 2 18 AUX 2 3 19 AUX 3 4 20 AUX 4 5 21 AUX 5 6 22 AUX 6 7 23 AUX 7 8 24 AUX 8 9 25 BUS 1 10 26 BUS 2 11 27 BUS 3 12 28 BUS 4 13 29 BUS 5 14 30 BUS 6 15 31 BUS 7 16 32 BUS 8 STEREO +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 0 +10 00 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 10 20 20 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 15 30 30 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 20 40 40 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 30 50 50 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 70 40 60 60 70 70 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 USER DEFINED KEYS 1 2 3 4 5 6 7 8 1 17 AUX 1 2 18 AUX 2 3 19 AUX 3 4 20 AUX 4 5 21 AUX 5 6 22 AUX 6 7 23 AUX 7 8 24 AUX 8 9 25 BUS 1 10 26 BUS 2 11 27 BUS 3 12 28 BUS 4 13 29 BUS 5 14 30 BUS 6 15 31 BUS 7 16 32 BUS 8 STEREO 01V96i (Slave) 01V96i (Master) 3. On the slave unit, press the DISPLAY ACCESS [PATCH] button repeatedly until the Patch | Out Patch page appears. 4. Assign the Bus signals to the channels that are used for the cascade connection. The following signals are available: Options Description CAS BUS1-BUS8 Bus 1-8 Cascade Outs CAS AUX1-AUX8 Aux Bus 1-8 Cascade Outs CAS ST-L, CAS ST-R Stereo Bus L & R Cascade Outs CASSOLOL, CASSOLOR Solo Bus L & R Cascade Outs The following display page is an example of integrating Bus 1-8, Aux Send 1-4, Stereo Bus, and Solo Bus signals via the ADAT IN and OUT connectors and two 8-channel digital I/O cards (such as MY8-AT). Tip: Patching may vary depending on the type and number of buses used for the cascade connection. Note: Since the number of channels available on the digital I/O card is limited, only Aux Sends 1-4 are cascaded in this example. Using a 16-channel digital I/O card (such as MY16-AT) enables you to cascade all buses. 5. On the master unit, press the DISPLAY ACCESS [PATCH] button repeatedly until the Patch | Cascade In page appears. 6. Select the Input Channels on the master unit to which the Bus signals are input from the Slave unit. The following display page is an example of receiving the slave unit's Bus 1-8, Aux Send 1-4, Stereo Bus, and Solo 01V96i-Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

Cascading Consoles
111
01V96i—Reference Manual
Other Functions
Cascading Consoles
The 01V96i features a Cascade Bus that enables cascade con-
nection. You can connect two 01V96is in cascade using the
digital inputs and outputs, or the OMNI IN and OMNI OUT
connectors. In this way, two consoles work just like one big
console, integrating each unit’s Buses 1–8, Aux Sends 1–8,
Stereo Bus, and Solo Bus.
The following functions are linked between two cascaded
01V96is via the MIDI IN and OUT ports.
Display page selection
Solo function
Fader Mode
Metering Position
Peak Hold On/Off
Meter Fast Fall on/off
Scene Store, Recall, and Title Edit
The following paragraphs explain how to make a cascade
connection using two 01V96is and the inputs and outputs of
the digital I/O card installed in the slot of each 01V96i.
1.
Install digital I/O cards into the slot on each
of two 01V96is.
2.
Connect two 01V96is as follows:
Connect the digital I/O card output on the transmitting
01V96i (slave) to the digital I/O card input on the receiv-
ing 01V96i (master).
Connect the ADAT IN connector on the master unit to
the ADAT OUT connector on the slave unit.
Connect the MIDI IN port on the master unit to the
MIDI OUT port on the slave unit using a MIDI cable.
Connect the MIDI OUT port on the master unit to the
MIDI IN port on the slave unit using a MIDI cable.
3.
On the slave unit, press the DISPLAY ACCESS
[PATCH] button repeatedly until the Patch |
Out Patch page appears.
4.
Assign the Bus signals to the channels that are
used for the cascade connection.
The following signals are available:
The following display page is an example of integrating
Bus 1–8, Aux Send 1–4, Stereo Bus, and Solo Bus signals
via the ADAT IN and OUT connectors and two 8-chan-
nel digital I/O cards (such as MY8-AT).
5.
On the master unit, press the DISPLAY
ACCESS [PATCH] button repeatedly until the
Patch | Cascade In page appears.
6.
Select the Input Channels on the master unit
to which the Bus signals are input from the
Slave unit.
The following display page is an example of receiving the
slave unit’s Bus 1–8, Aux Send 1–4, Stereo Bus, and Solo
Tip:
To link functions and parameters (excluding the Solo func-
tion), turn on the Cascade COMM Link check box on the Setup
| Prefer1 page (see page 109).
The Solo function is always linked regardless of the status of the
Cascade COMM Link check box.
16
15
13
12
11
10
9
8
7
6
4
3
2
1
5
14
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
7
8
9
10
11
12
13
14
15
16
13
14
15
16
16
15
13
12
11
10
9
8
7
6
4
3
2
1
5
14
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
7
8
9
10
11
12
13
14
15
16
13
14
15
16
MY8-AT
etc.
SLOT
MY8-AT
etc.
SLOT
01V96i (Slave)
01V96i (Master)
OUT
IN
ADAT
OUT
connector
MIDI
IN/OUT
connector
ADAT
IN
connector
MIDI
IN/OUT
connector
Options
Description
CAS BUS1–BUS8
Bus 1–8 Cascade Outs
CAS AUX1–AUX8
Aux Bus 1–8 Cascade Outs
CAS ST-L, CAS ST-R
Stereo Bus L & R Cascade
Outs
CASSOLOL, CASSOLOR
Solo Bus L & R Cascade
Outs
Tip:
Patching may vary depending on the type and number
of buses used for the cascade connection.
Note:
Since the number of channels available on the digital
I/O card is limited, only Aux Sends 1–4 are cascaded in this
example. Using a 16-channel digital I/O card (such as
MY16-AT) enables you to cascade all buses.