Yamaha 01V96i Reference Manual - Page 16
Setting the Transfer Format for Higher Sampling Rates
![]() |
View all Yamaha 01V96i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
16 Analog I/O & Digital I/O Setting the Transfer Format for Higher Sampling Rates To operate the 01V96i at higher sampling frequencies (88.2 kHz or 96 kHz) and transfer digital audio signals to and from connected external devices, you must set the data transfer format in accordance with the sampling frequencies supported by the external devices. 1. Press the DISPLAY ACCESS [DIO/SETUP] but- ton repeatedly until the DIO/Setup | Word Clock page appears. 2. Select INT88.2k or INT96k as the wordclock source. Note: When the 01V96i operates at a high sampling rate (88.2 kHz or 96 kHz), only two internal effects processors are available. 3. Press the DISPLAY ACCESS [DIO/SETUP] but- ton repeatedly until the DIO/Setup | Format page appears. 1 • DOUBLE SPEED In Double Speed mode, digital audio data is received and transmitted at the current high sampling rate (i.e., 88.2 kHz or 96 kHz). Select this mode if the devices that support the higher sampling rates transmit or receive data. Note: You can select this setting only for slots in which a digital I/O card that inputs/outputs double-speed digital audio data (e.g., MY8-AE96, MY8-AE96S) is installed. • SINGLE In Single mode, digital audio data is received and transmitted at a sampling rate that is half (44.1/48 kHz) the current higher sampling rate of the 01V96i. For example, this is useful when you want to receive 44.1 kHz digital signals from an external digital device while the 01V96i is operating at 88.2 kHz. Note: You cannot select this setting for slots in which a digital I/O card that inputs/outputs double-speed digital audio data (e.g., MY8-AE96, MY8-AE96S) is installed. Tip: The parameter fields display "-" if the slot contains no I/O card or if an AD/DA card or other I/O card that does not allow you to set the transfer format has been installed. 4. Use the cursor buttons to move the cursor to an IN/OUT parameter field (1), then rotate the Parameter wheel or press the [INC]/[DEC] buttons to set the data transfer format. The IN/OUT parameters are used to set one of the following data transfer formats for each slot input and output. • DOUBLE CHANNEL In Double Channel mode, digital audio data is received and transmitted as mono signals at a sampling rate that is exactly half (44.1/48 kHz) the current higher sampling rate. Data is handled by two channels. This is useful when you want to transfer data between the 01V96i operating at a higher sampling rate and an external digital device that supports 44.1/48 kHz. Note: Double Channel mode reduces the total number of inputs or outputs on the corresponding slot. The even-numbered channels are disabled. 01V96i-Reference Manual
![](/manual_guide/products/yamaha-01v96i-reference-manual-08a5520/16.png)