Dell Force10 MXL Blade MXL 10/40GbE Switch IO Module FTOS Command Line Referen - Page 60
show environment all Command Example
View all Dell Force10 MXL Blade manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
www.dell.com | support.dell.com Parameters all stack-unit unit-id thermal sensor Enter the keyword all to view all components. Enter the keyword stack-unit followed by the unit-id to display information on a specific stack member. Range: 0 to 5. Enter the keyword thermal-sensor to view all components. Command Modes EXEC EXEC Privilege Command History Usage Information Version 8.3.16.1 Introduced on MXL 10/40GbE Switch IO Module Figure 4-13 shows the output of the show environment fan command as it appears prior to FTOS 7.8.1.0. Example Figure 4-13. show environment all Command Example FTOS#show environment all -- Unit Environment Status -- Unit Status Temp Voltage * 0 online 47C ok * Management Unit -- Thermal Sensor Readings (deg C) -- Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7 Sensor8 Sensor9 0 50 52 53 53 54 48 57 57 53 56 FTOS# Example Figure 4-14. show environment stack-unit Command Example FTOS#show environment stack-unit 0 -- Unit Environment Status -- Unit Status Temp Voltage 0* online 49C ok * Management Unit Example Figure 4-15. show environment thermal-sensor Command Example FTOS#show environment thermal-sensor -- Thermal Sensor Readings (deg C) -- Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7 Sensor8 Sensor9 0 50 52 53 53 54 48 57 57 53 56 * Management Unit FTOS# 60 | Control and Monitoring