IBM 84885BU User Manual - Page 136
built-in, fault, messages
View all IBM 84885BU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Host built-in self test (BIST) Note: See "System replaceable units" on page 131 to determine which components should be replaced by a field service technician. Message Action Host fail (level-informational; built-in self-test for the host failed) 1. Reseat the microprocessor. 2. Replace the microprocessor. Bus fault messages Note: See "System replaceable units" on page 131 to determine which components should be replaced by a field service technician. Bus fault messages Message Action Failure reading 12C device. Check devices on bus 0. 1. If installed, reseat the I2C cable between RSA2 and the RSA2 connector on the system board. 2. DIMMs. 3. System board. Failure reading 12C device. Check devices on bus 1. 1. Reseat the I2C cable between the operator information panel and system board. 2. Operator information panel. 3. System board. Failure reading 12C device. Check devices on bus 2. 1. Reseat the cable between system board and the power supply (power cage assembly, if installed) (JPWR1, JPWR2). 2. Power cage assembly, if installed. 3. Power supply. 4. System board. Failure reading 12C device. Check devices on bus 3. 1. Reseat the cable between the SCSI backplane and connector on system board. 2. SCSI backplane. 3. System board. Failure reading I2C device. Check device on bus 4. v System board 126 xSeries 226 Type 8488 and 8648: Hardware Maintenance Manual and Troubleshooting Guide