Memory, Volume
UPC - 027108936673
View all Yamaha A3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Data Configuration and Handling The point to remember here is that each disk volume corresponds exactly to a full set of main-memory data. As the next illustration shows, the A3000 saves all main-memory data into a single volume. When you reload the volume, you restore the main memory to its exact state at the time of the data save. Memory System Parameters Sequence Data Sample A Wave data Sample parameters Sample B Wave data Sample parameters Sample C Wave data Sample parameters Program 001 Program Parameters Program 002 Program Parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters Program 128 Program Parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters Volume System Parameters Sequence Data Program 001 Program Parameters Program 002 Program Parameters Sample A Wave data Sample parameters Sample B Wave data Sample parameters Sample C Wave data Sample parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters Program 128 Program Parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters ToPgm switch Easy-edit parameters 82 Chapter 3 Basics