Ricoh Aficio SP 8300DN Manuals - Page 90
a Sample Print, Locked Print, Hold Print, Print, or Stored Print file
View all Ricoh Aficio SP 8300DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
3. Troubleshooting Message "Classification Code is incorrect." "Collate has been cancelled." "Command Error" "Compressed Data Error." "Data storage error." Cause Solution The classification code is not supported by the printer driver. Select Optional for the classification code. For details about how to specify classification code settings, see "Registering Classification Codes", Operating Instructions. Collate was canceled. Decrease the number of files sent to the printer or install the optional SDRAM module. For details about installing SDRAM module, see "Installing the SDRAM module", Operating Instructions. An RPCS command error occurred. Check that the communication between a device and the printer is working correctly. The printer detected corrupt compressed data. • Check the connection between the computer and the printer. • Check that the program you used to compress the data is functioning correctly. You tried to print a Sample Print, Locked Print, Hold Print, or Stored Print file while the hard disk was not installed. The hard disk is required when printing a Sample Print, Locked Print, Hold Print, or Stored Print. If the message appear after installing the hard disk, contact your service representative. 88