ZyXEL Vantage CNM User Guide - Page 99
Table 27
View all ZyXEL Vantage CNM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Chapter 5 Device Network Settings Note: Consult the manual of your WAN device connected to your dial backup port for specific AT commands. Figure 41 Device Operation > Device Configuration > Network > WAN > Dial Backup > Advanced (ZyNOS ZyWALL) The following table describes the labels in this screen. Table 27 Device Operation > Device Configuration > Network > WAN > Dial Backup > Advanced (ZyNOS ZyWALL) LABEL DESCRIPTION EXAMPLE AT Command Strings Dial Type the AT Command string to make a call. atdt Drop Type the AT Command string to drop a call. "~" represents a one second wait, for example, "~~~+++~~ath" can be used if your modem has a slow response time. ~~+++~~ ath Answer Type the AT Command string to answer a call. ata Drop DTR When Select this check box to have the device drop the DTR Hang Up (Data Terminal Ready) signal after the "AT Command String: Drop" is sent out. AT Response Strings CLID Type the keyword that precedes the CLID (Calling Line Identification) in the AT response string. This lets the device capture the CLID in the AT response string that comes from the WAN device. CLID is required for CLID authentication. NMBR Called ID Type the keyword preceding the dialed number. Speed Type the keyword preceding the connection speed. CONNECT Call Control Vantage CNM User's Guide 99