Dell PowerVault MD3200 CLI Guide - Page 190

Set Foreign Physical Disk to Native

Page 190 highlights

Parameters Parameter enclosure id Description Service tag of the RAID enclosure or the expansion enclosure for which you are setting the enclosure ID. You must put quotation marks (" ") around the Service Tag. Specifies the value for the RAID enclosure or expansion enclosure ID. Valid values are 00 through 99. You do not need to put parentheses around the enclosure ID value. Set Foreign Physical Disk to Native A physical disk is considered to be native when it is a part of a storage array disk group. A physical disk is considered to be foreign when it does not belong to a storage array disk group or when it fails to be imported with the physical disks of a disk group that are transferred to a new storage array. The latter failure creates an incomplete disk group on the new storage array. Run this command to add the missing (foreign) physical disks back into their original disk group and to make them part of the new storage array disk group configuration of the new storage array. Use this operation for emergency recovery only: when one or more physical disks need to be changed from a foreign physical disk status and returned to a native status within their original disk group. CAUTION: Using this command for purposes other than what is stated above might result in data corruption or data loss without notification. Syntax set (physicalDisk [enclosureID,slotID] | physicalDisks [enclosureID1,slotID1 enclosureID2, slotID2 ... enclosureIDn,slotIDn]| allPhysicalDisks) nativeState 190 Script Commands

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279

190
Script Commands
Parameters
Set Foreign Physical Disk to Native
A physical disk is considered to be native when it is a part of a storage array
disk group. A physical disk is considered to be foreign when it does not belong
to a storage array disk group or when it fails to be imported with the physical
disks of a disk group that are transferred to a new storage array. The latter
failure creates an incomplete disk group on the new storage array.
Run this command to add the missing (foreign) physical disks back into their
original disk group and to make them part of the new storage array disk group
configuration of the new storage array.
Use this operation for emergency recovery only: when one or more physical
disks need to be changed from a foreign physical disk status and returned to a
native status within their original disk group.
CAUTION:
Using this command for purposes other than what is stated above
might result in data corruption or data loss without notification.
Syntax
set (physicalDisk [enclosureID,slotID] |
physicalDisks [enclosureID1,slotID1 enclosureID2,
slotID2 ... enclosureIDn,slotIDn]|
allPhysicalDisks) nativeState
Parameter
Description
enclosure
Service tag of the RAID enclosure or the
expansion enclosure for which you are setting the
enclosure ID. You must put quotation marks (" ")
around the Service Tag.
id
Specifies the value for the RAID enclosure or
expansion enclosure ID. Valid values are
00
through
99
. You do not need to put parentheses
around the enclosure ID value.