HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 105

HP Ethernet Events, Source in Windows Event Log

Page 105 highlights

Event ID Event Severity 12560 Error 12586 Error 12589 Error 12591 Error 12593 Error 12595 Error 12627 Warning 12863 Error Event Description OS run-time critical shutdown occurred. Probable Cause: The OS has caused the system to shut down. Recommended Action: Look at OS logs and crash data to determine why the system shut down. The amount of power expected to be drawn by the currently operating hardware is greater than the rating of the currently operating Bulk Power Supplies (BPS). Probable Cause: A bulk power supply has failed or was removed when the system had the minimal number of required bulk power supplies. Recommended Action: Replace the failed or removed bulk power supply. WBEM EventID: 7250. WBEM ProviderName: FPL_IndicationProvider. Bulk power supply (BPS) redundancy has been lost on one or more row(s) of power supplies in the complex. The further loss of a single BPS or an AC grid will most likely result in the shutdown of partitions. Probable Cause: An AC source has been lost. Recommended Action: Verify that the chassis is connected to working power grid(s). WBEM EventID: 7253. WBEM ProviderName: FPL_IndicationProvider. AC redundancy has been lost on one or more power supplies in the complex. The further loss of a single Bulk Power Supply (BPS) or the other AC grid will most likely result in the shutdown of partitions. Probable Cause: A configuration change has been made to the system that changes the amount of power used. Recommended Action: Relook at the configuration changes. WBEM EventID: 7255. WBEM ProviderName: FPL_IndicationProvider. The fans that cool a region of the system are not redundant. If an additional fan fails or is removed from this cooling domain, the partitions on this system will be shut down to prevent damage. Probable Cause: One or more fans in the cooling domain have been removed or are not functioning properly. Recommended Action: Removed failed fan (if any) and insert working fan. WBEM EventID: 7256. WBEM ProviderName: FPL_IndicationProvider. An insufficient number of fans are working in a cooling domain to permit system operation. Running partitions will be shut down immediately to prevent damage due to excessive heat. Probable Cause: More than one fan in a cooling domain have been removed or are not functioning properly. Recommended Action: Remove failed fan(s), if any, and insert working fans. WBEM EventID: 7258. WBEM ProviderName: FPL_IndicationProvider. Operating system is not using all available processors for the current system. Probable Cause: Operating system license doesn't allow all processors to be used, or some processors are disabled / deconfigured. Recommended Action: Verify the correct operating system license to be used; Verify if all processors are enabled. A Fabric Message Processor (FMP) has unexpectedly reset. The system has recovered from the problem. Probable Cause: There is a firmware problem. Recommended Action: Verify that the most recent firmware is installed on the system. WBEM EventID: 7622. WBEM ProviderName: FPL_IndicationProvider. HP Ethernet Events Source in Windows Event Log: HP Ethernet Event ID Event Severity Event Description 1 Error An Ethernet provider encountered an unrecoverable error. 2 Error A network interface has failed. An Ethernet adapter's status changed from OK to Error, or an Ethernet team's status changed to Error from another state. 3 Information A failed network interface was restored. An Ethernet port's status changed from an Error state to a non-Error state. 4 Warning An Ethernet team's redundancy has decreased. A team member has changed to failed or degraded state. HP Ethernet Events 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
OS run-time critical shutdown occurred. Probable Cause: The OS has caused the
system to shut down. Recommended Action: Look at OS logs and crash data to
determine why the system shut down.
Error
12560
The amount of power expected to be drawn by the currently operating hardware is
greater than the rating of the currently operating Bulk Power Supplies (BPS). Probable
Cause: A bulk power supply has failed or was removed when the system had the
minimal number of required bulk power supplies. Recommended Action: Replace
the failed or removed bulk power supply. WBEM EventID: 7250. WBEM
ProviderName: FPL_IndicationProvider.
Error
12586
Bulk power supply (BPS) redundancy has been lost on one or more row(s) of power
supplies in the complex. The further loss of a single BPS or an AC grid will most
likely result in the shutdown of partitions. Probable Cause: An AC source has been
lost. Recommended Action: Verify that the chassis is connected to working power
grid(s). WBEM EventID: 7253. WBEM ProviderName: FPL_IndicationProvider.
Error
12589
AC redundancy has been lost on one or more power supplies in the complex. The
further loss of a single Bulk Power Supply (BPS) or the other AC grid will most likely
result in the shutdown of partitions. Probable Cause: A configuration change has
been made to the system that changes the amount of power used. Recommended
Action: Relook at the configuration changes. WBEM EventID: 7255. WBEM
ProviderName: FPL_IndicationProvider.
Error
12591
The fans that cool a region of the system are not redundant. If an additional fan fails
or is removed from this cooling domain, the partitions on this system will be shut
down to prevent damage. Probable Cause: One or more fans in the cooling domain
have been removed or are not functioning properly. Recommended Action: Removed
failed fan (if any) and insert working fan. WBEM EventID: 7256. WBEM
ProviderName: FPL_IndicationProvider.
Error
12593
An insufficient number of fans are working in a cooling domain to permit system
operation. Running partitions will be shut down immediately to prevent damage
due to excessive heat. Probable Cause: More than one fan in a cooling domain have
been removed or are not functioning properly. Recommended Action: Remove failed
fan(s), if any, and insert working fans. WBEM EventID: 7258. WBEM ProviderName:
FPL_IndicationProvider.
Error
12595
Operating system is not using all available processors for the current system. Probable
Cause: Operating system license doesn't allow all processors to be used, or some
processors are disabled / deconfigured. Recommended Action: Verify the correct
operating system license to be used; Verify if all processors are enabled.
Warning
12627
A Fabric Message Processor (FMP) has unexpectedly reset. The system has recovered
from the problem. Probable Cause: There is a firmware problem. Recommended
Action: Verify that the most recent firmware is installed on the system. WBEM
EventID: 7622. WBEM ProviderName: FPL_IndicationProvider.
Error
12863
HP Ethernet Events
Source in Windows Event Log:
HP Ethernet
Event Description
Event
Severity
Event ID
An Ethernet provider encountered an unrecoverable error.
Error
1
A network interface has failed. An Ethernet adapter's status changed from OK to
Error, or an Ethernet team's status changed to Error from another state.
Error
2
A failed network interface was restored. An Ethernet port's status changed from an
Error state to a non-Error state.
Information
3
An Ethernet team's redundancy has decreased. A team member has changed to failed
or degraded state.
Warning
4
HP Ethernet Events
105