HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 95
The System Firmware call to PAL_COPY_INFO failed. Probable Cause: Contact
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Event ID Event Severity 11904 Warning 11905 Warning 11932 Error 11933 Error 11960 Warning 11961 Warning 11962 Warning 11964 Error 11966 Error 11967 Error 11968 Error 11969 Error 11970 Warning Event Description Fabric was unable to generate a Skyline CSR address. Data field: cell number [63:56] and return value from address function [31:0]. Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5171. WBEM ProviderName: FPL_IndicationProvider. Firmware was unable to generate a Skyline CSR address. Data field: cell number [63:56] | return value [31:0]. Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5172. WBEM ProviderName: FPL_IndicationProvider. Invalid or no OS boot rendezvous entry point for target CPU. Probable Cause: OS or firmware bugs Recommended Action: Call HP support. WBEM EventID: 5174. WBEM ProviderName: FPL_IndicationProvider. Checksum verification failed for OS_BOOT_RENDEZ entry point. Probable Cause: Software data corruption Recommended Action: Call HP support. WBEM EventID: 5175. WBEM ProviderName: FPL_IndicationProvider. The System Firmware call to PAL_COPY_INFO failed. Probable Cause: Contact Engineering, This is a bug. WBEM EventID: 5176. WBEM ProviderName: FPL_IndicationProvider. The System Firmware call to PAL_COPY_PAL failed. Probable Cause: Contact Engineering, This is a bug. WBEM EventID: 5177. WBEM ProviderName: FPL_IndicationProvider. The System Firmware call to PAL_CACHE_FLUSH failed. Probable Cause: Contact Engineering, This is a bug. WBEM EventID: 5178. WBEM ProviderName: FPL_IndicationProvider. Cell on line add/delete is not initialized. Probable Cause: Cell online add/delete was attempted but the colad subsystem failed to initialize. Recommended Action: Contact HP support. When this event is emitted, cell online add/delete is not usable. WBEM EventID: 6897. WBEM ProviderName: FPL_IndicationProvider. An FPARs component on which cell on-line add/delete depends is broken or missing. Probable Cause: FPARs component on which cell on line add/delete depends is broken or missing. Recommended Action: Do not use COLAD is FPARs mode. WBEM EventID: 6899. WBEM ProviderName: FPL_IndicationProvider. Cell on-line add/delete in FPARs mode failed to get the FPARs semaphore. Probable Cause: Cell on line add/delete in FPARs mode failed to get the FPARs semaphore. Recommended Action: Do not use cell on line add/delete in FPARs mode. WBEM EventID: 6900. WBEM ProviderName: FPL_IndicationProvider. More than one processor from an FPAR called into cell on-line add/delete. Probable Cause: More than one processor from an FPAR called into cell on line add/delete Recommended Action: Do not use cell on line add/delete in FPARs mode. WBEM EventID: 6901. WBEM ProviderName: FPL_IndicationProvider. All FPARs processors failed to rendezvous during a cell on line add/delete operation. Probable Cause: All FPARs processors failed to rendezvous during a cell on line add/delete operation. Recommended Action: Do not use cell on line add/delete in FPARs mode. WBEM EventID: 6902. WBEM ProviderName: FPL_IndicationProvider. Encountered unexpected error during cell OLA activity. Probable Cause: New cell cannot communicate with existing partition. Cell OLA failed. Recommended Action: Existing partition can continue to run, new cell cannot be added to the partition. WBEM EventID: 5179. WBEM ProviderName: FPL_IndicationProvider. Platform Events 95