Prototype CPU installed. Probable Cause: A Prototype CPU is installed. Recommended

Page 34 highlights

Event ID Event Severity 5732 Error 5733 Error 5734 Error 5735 Error 5737 Warning 5738 Warning 5740 Warning 5741 Warning 5742 Error 5743 Error 5744 Warning 5745 Warning 5746 Error 5747 Warning Event Description Error creating the acpi_hw node. Probable Cause: May be out of malloc space or a previous tree error prevented this from being successful. Check for earlier errors. WBEM EventID: 2460. WBEM ProviderName: FPL_IndicationProvider. Error encountered creating or initializing the ipmi node. Probable Cause: Possibly out of memory or an earlier error left the tree in an unusable state. WBEM EventID: 2461. WBEM ProviderName: FPL_IndicationProvider. some processors not compatible. Probable Cause: Installed processors are not of compatible models or families Recommended Action: Replace processors with compatible ones if all processors are to be used. WBEM EventID: 481. WBEM ProviderName: FPL_IndicationProvider. caches sizes are inconsistent. Probable Cause: Processors with different cache sizes are installed in the system. Recommended Action: Replace processors with compatible ones if all processors are to be used. WBEM EventID: 482. WBEM ProviderName: FPL_IndicationProvider. selecting new monarch. Probable Cause: The monarch processor was not the lowest stepping processor installed within the cell. Recommended Action: No action is required. FW takes action automatically. To avoid this event, be sure that the monarch processor is the lowest stepping of processor in the system. WBEM EventID: 484. WBEM ProviderName: FPL_IndicationProvider. monarch not lowest stepping. Probable Cause: The monarch processor has a stepping that is greater than a slave processor installed in the system. Recommended Action: No action is needed. If problem persists, update System FW or contact your HP representative for support. WBEM EventID: 485. WBEM ProviderName: FPL_IndicationProvider. processors are over clocked. Probable Cause: FSB speed faster than the capabilities of the processors Recommended Action: If multiple CPU's report this issue, check the BMC. If only one reports this issue, replace the CPU. If problem persists, contact HP support. WBEM EventID: 487. WBEM ProviderName: FPL_IndicationProvider. cpu access error on processor info area. Probable Cause: An early version of CPU or a bad info ROM. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 488. WBEM ProviderName: FPL_IndicationProvider. PAL A was not executed - HALT. Probable Cause: PAL_A has not been executed. Recommended Action: Contact your HP representative for support. WBEM EventID: 489. WBEM ProviderName: FPL_IndicationProvider. PAL B was not executed - HALT. Probable Cause: PAL_B has not been executed. Recommended Action: Contact your HP representative for support. WBEM EventID: 490. WBEM ProviderName: FPL_IndicationProvider. Prototype CPU installed. Probable Cause: A Prototype CPU is installed. Recommended Action: Replace CPU with a production CPU. WBEM EventID: 491. WBEM ProviderName: FPL_IndicationProvider. final boot rendezvous monarch watchdog timeout. Probable Cause: A watchdog timer has expired and determined that a monarch is dead. Recommended Action: Reboot, if problem persists, replace CPU. WBEM EventID: 492. WBEM ProviderName: FPL_IndicationProvider. Supplemental cpu tests generated an unexpected result. Probable Cause: A CPU failed supplemental selftests. Replace the offending CPU. WBEM EventID: 2462. WBEM ProviderName: FPL_IndicationProvider. A multi-bit error was found while reading a XBC CSR. Probable Cause: Possibly bad link or cell connection. Recommended Action: Reset partition, and check hardware associated with event data. WBEM EventID: 493. WBEM ProviderName: FPL_IndicationProvider. 34 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Error creating the acpi_hw node. Probable Cause: May be out of malloc space or a
previous tree error prevented this from being successful. Check for earlier errors.
WBEM EventID: 2460. WBEM ProviderName: FPL_IndicationProvider.
Error
5732
Error encountered creating or initializing the ipmi node. Probable Cause: Possibly
out of memory or an earlier error left the tree in an unusable state. WBEM EventID:
2461. WBEM ProviderName: FPL_IndicationProvider.
Error
5733
some processors not compatible. Probable Cause: Installed processors are not of
compatible models or families Recommended Action: Replace processors with
compatible ones if all processors are to be used. WBEM EventID: 481. WBEM
ProviderName: FPL_IndicationProvider.
Error
5734
caches sizes are inconsistent. Probable Cause: Processors with different cache sizes
are installed in the system. Recommended Action: Replace processors with compatible
ones if all processors are to be used. WBEM EventID: 482. WBEM ProviderName:
FPL_IndicationProvider.
Error
5735
selecting new monarch. Probable Cause: The monarch processor was not the lowest
stepping processor installed within the cell. Recommended Action: No action is
required. FW takes action automatically. To avoid this event, be sure that the monarch
processor is the lowest stepping of processor in the system. WBEM EventID: 484.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5737
monarch not lowest stepping. Probable Cause: The monarch processor has a stepping
that is greater than a slave processor installed in the system. Recommended Action:
No action is needed. If problem persists, update System FW or contact your HP
representative for support. WBEM EventID: 485. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5738
processors are over clocked. Probable Cause: FSB speed faster than the capabilities
of the processors Recommended Action: If multiple CPU's report this issue, check
the BMC. If only one reports this issue, replace the CPU. If problem persists, contact
HP support. WBEM EventID: 487. WBEM ProviderName: FPL_IndicationProvider.
Warning
5740
cpu access error on processor info area. Probable Cause: An early version of CPU or
a bad info ROM. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 488. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5741
PAL A was not executed - HALT. Probable Cause: PAL_A has not been executed.
Recommended Action: Contact your HP representative for support. WBEM EventID:
489. WBEM ProviderName: FPL_IndicationProvider.
Error
5742
PAL B was not executed - HALT. Probable Cause: PAL_B has not been executed.
Recommended Action: Contact your HP representative for support. WBEM EventID:
490. WBEM ProviderName: FPL_IndicationProvider.
Error
5743
Prototype CPU installed. Probable Cause: A Prototype CPU is installed. Recommended
Action: Replace CPU with a production CPU. WBEM EventID: 491. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5744
final boot rendezvous monarch watchdog timeout. Probable Cause: A watchdog
timer has expired and determined that a monarch is dead. Recommended Action:
Reboot, if problem persists, replace CPU. WBEM EventID: 492. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5745
Supplemental cpu tests generated an unexpected result. Probable Cause: A CPU
failed supplemental selftests. Replace the offending CPU. WBEM EventID: 2462.
WBEM ProviderName: FPL_IndicationProvider.
Error
5746
A multi-bit error was found while reading a XBC CSR. Probable Cause: Possibly bad
link or cell connection. Recommended Action: Reset partition, and check hardware
associated with event data. WBEM EventID: 493. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5747
34
WBEM Provider Event Tables