HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 28
The Stable Complex Profile Sequence Id is invalid. Probable Cause: Push out a new
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Event ID Event Severity 5548 Error 5550 Error 5556 Error 5557 Error 5558 Error 5559 Error 5560 Error 5566 Error 5567 Error 5568 Error 5569 Error 5570 Error 5572 Error 5573 Warning 5574 Warning 5575 Error 5577 Warning Event Description This indicates the loss of lockstep during the MCA path. Probable Cause: The cell will take up a few more error logging steps independently before resetting itself. WBEM EventID: 428. WBEM ProviderName: FPL_IndicationProvider. The PD level cell rendezvous failed. Probable Cause: This means that the cells will independently step through some of the error logging code and then reset themselves. WBEM EventID: 429. WBEM ProviderName: FPL_IndicationProvider. It stands for diagnosis of catastrophic errors in the PIN block of concorde. Probable Cause: This means that the cell will be reset. WBEM EventID: 557. WBEM ProviderName: FPL_IndicationProvider. The cell monarch cpu has failed. Probable Cause: The monarch cpu will be deconfigured. WBEM EventID: 1020. WBEM ProviderName: FPL_IndicationProvider. This indicates that the cell missed the rendezvous at the partition level. Probable Cause: The cell will independently step through some of the error logging steps and then finally reset itself. WBEM EventID: 559. WBEM ProviderName: FPL_IndicationProvider. This means that the PD monarch timedout. Probable Cause: The cell will be reset ; also the partition will be reset. WBEM EventID: 560. WBEM ProviderName: FPL_IndicationProvider. SetViewRoot on a remote cell failed. Probable Cause: Inter Processor interrupts failed. Be sure that the partition rendezvous was successfully completed. Reset. WBEM EventID: 2452. WBEM ProviderName: FPL_IndicationProvider. Failed to update CSR contents. Probable Cause: Coherency controller on cell sending event is suspect. Recommended Action: Provide event data to HP support center for assistance. WBEM EventID: 2431. WBEM ProviderName: FPL_IndicationProvider. This indicates the failure in collecting the Complex profile info. Probable Cause: The partition level memory interleaving cannot continue without the appropriate information. WBEM EventID: 563. WBEM ProviderName: FPL_IndicationProvider. This chassis code indicates the failure in collecting the cell info. Probable Cause: The partition level memory will fail. WBEM EventID: 564. WBEM ProviderName: FPL_IndicationProvider. This indicates the failure in updating the GNI info of the cell with CLM. Probable Cause: The partition level memory will fail at this point. WBEM EventID: 565. WBEM ProviderName: FPL_IndicationProvider. This indicates the failure in adjusting the mem info with Minimum ZI req. Probable Cause: This will cause the partition level memory to exit cell interleaving. WBEM EventID: 566. WBEM ProviderName: FPL_IndicationProvider. Complex Profile A has a checksum error. Probable Cause: Reconfigure the system get a new complex profile distributed and reset. WBEM EventID: 2453. WBEM ProviderName: FPL_IndicationProvider. A Checksum error was encountered in the dynamic profile. Probable Cause: Push out a new complex profile and reset. WBEM EventID: 1861. WBEM ProviderName: FPL_IndicationProvider. A checksum error occurred on the Partition Profile. Probable Cause: Push out a new complex profile and reboot. WBEM EventID: 1862. WBEM ProviderName: FPL_IndicationProvider. The Stable Complex Profile Sequence Id is invalid. Probable Cause: Push out a new complex profile and reset the system. The cell will be waiting for reconfiguration. WBEM EventID: 2454. WBEM ProviderName: FPL_IndicationProvider. The Dynamic Complex Profile Sequence ID is invalid. Probable Cause: Push out a new complex profile. WBEM EventID: 2455. WBEM ProviderName: FPL_IndicationProvider. 28 WBEM Provider Event Tables