Event ID Event Severity 10830 Warning 10832 Warning 10833 Warning 10842 Warning 10853 Error 10871 Error 10927 Error 10936 Warning Event Description fPars-mode EFI variable is set to enable fPars operation but no fPars are actually enabled to boot. So the server boots in hard partition mode. Probable Cause: fPars-mode EFI variable is set to enable fPars operation but no fPars are actually enabled to boot. So the server boots in hard partition mode. This is a configuration usage problem, possibly a user error such as might occur if a previously bootable config was made unbootable by setting the enabled fPar existence variables, e.g., 'fPar0', 'fPar1', ... 'fParN' to 0x00 (disabled) and then rebooting Recommended Action: Use the configuration tool released with the OS to disable fPars mode or to configure and enable bootable fPars. WBEM EventID: 4700. WBEM ProviderName: FPL_IndicationProvider. An fPar was directed to reset using the ESIT DirectedfParResetAndMigrate() service but the target (recipient) fPar of the resources is in a state that cannot receive ownership of these resources. Probable Cause: An fPar was directed to reset using the ESIT DirectedfParResetAndMigrate() service but the target (recipient) fPar of the resources is in a state that cannot receive ownership of these resources. Recommended Action: Use the configuration tool released with the OS to correctly assign these resources to an fPar and reset that fPar so they will be claimed. WBEM EventID: 4701. WBEM ProviderName: FPL_IndicationProvider. Firmware error setting the NVRAM value of preferred-bsp for the vPars monitor. The partition will boot using the PD monarch, but the value of preferred-bsp may not match this CPU. Probable Cause: Firmware could not store to the NVRAM holding the EFI preferred-bsp variable Recommended Action: Reset the server, restore factory default NVRAM and reconfigure soft partitions. WBEM EventID: 4702. WBEM ProviderName: FPL_IndicationProvider. Unable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches Fabric Phase3. Data field: (XBC port 48) | (XBC ID 32) | (route). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4704. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred. IPF firmware owned the processor interrupt vector table (IVT) at the time of the interrupt. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 4705. WBEM ProviderName: FPL_IndicationProvider. SBA call to LBA SetDeviceMask method fails. Probable Cause: SBA call to LBA SetDeviceMask method fails. Recommended Action: Disable rope in non-mca path, error exit in MCA path. WBEM EventID: 4766. WBEM ProviderName: FPL_IndicationProvider. LBA slot device scan error. Probable Cause: The LBA component detected a card in a PCI slot, but got no response from config register requests to the card. Recommended Action: Reseat or replace the PCI card. WBEM EventID: 4820. WBEM ProviderName: FPL_IndicationProvider. There is none (or inadequate) memory slice resource assigned to the fPar so it cannot boot its instance. The fPar will be disabled (enter a spinloop) because it cannot boot, or if in vPars mode will return control to the monitor. Probable Cause: There is no Memory owned by the soft partition (fPar) whose CPU emitted this event. Recommended Action: Reconfigure the soft partition containing the CPU that emitted this event and be sure to give memory resources to that soft partition before reset of that partition. Until doing so, this soft partition will be unbootable and emit this event on each attempt. WBEM EventID: 4708. WBEM ProviderName: FPL_IndicationProvider. Platform Events 85

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
fPars-mode EFI variable is set to enable fPars operation but no fPars are actually
enabled to boot. So the server boots in hard partition mode. Probable Cause:
fPars-mode EFI variable is set to enable fPars operation but no fPars are actually
enabled to boot. So the server boots in hard partition mode. This is a configuration
usage problem, possibly a user error such as might occur if a previously bootable
config was made unbootable by setting the enabled fPar existence variables, e.g.,
'fPar0', 'fPar1', ... 'fParN' to 0x00 (disabled) and then rebooting Recommended Action:
Use the configuration tool released with the OS to disable fPars mode or to configure
and enable bootable fPars. WBEM EventID: 4700. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10830
An fPar was directed to reset using the ESIT DirectedfParResetAndMigrate() service
but the target (recipient) fPar of the resources is in a state that cannot receive
ownership of these resources. Probable Cause: An fPar was directed to reset using
the ESIT DirectedfParResetAndMigrate() service but the target (recipient) fPar of the
resources is in a state that cannot receive ownership of these resources. Recommended
Action: Use the configuration tool released with the OS to correctly assign these
resources to an fPar and reset that fPar so they will be claimed. WBEM EventID: 4701.
WBEM ProviderName: FPL_IndicationProvider.
Warning
10832
Firmware error setting the NVRAM value of preferred-bsp for the vPars monitor.
The partition will boot using the PD monarch, but the value of preferred-bsp may
not match this CPU. Probable Cause: Firmware could not store to the NVRAM holding
the EFI preferred-bsp variable Recommended Action: Reset the server, restore factory
default NVRAM and reconfigure soft partitions. WBEM EventID: 4702. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10833
Unable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches
Fabric Phase3. Data field: (XBC port 48) | (XBC ID 32) | (route). Probable Cause:
System firmware was unable to write a fabric hardware register. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 4704. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10842
An unrecoverable processor interrupt occurred. IPF firmware owned the processor
interrupt vector table (IVT) at the time of the interrupt. Probable Cause: Probable
bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The
event data field contains the IVT offset applicable to the interrupt. See table 5-7
(Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action:
Provide console log containing register dump to HP Customer Engineer. WBEM
EventID: 4705. WBEM ProviderName: FPL_IndicationProvider.
Error
10853
SBA call to LBA SetDeviceMask method fails. Probable Cause: SBA call to LBA
SetDeviceMask method fails. Recommended Action: Disable rope in non-mca path,
error exit in MCA path. WBEM EventID: 4766. WBEM ProviderName:
FPL_IndicationProvider.
Error
10871
LBA slot device scan error. Probable Cause: The LBA component detected a card in
a PCI slot, but got no response from config register requests to the card. Recommended
Action: Reseat or replace the PCI card. WBEM EventID: 4820. WBEM ProviderName:
FPL_IndicationProvider.
Error
10927
There is none (or inadequate) memory slice resource assigned to the fPar so it cannot
boot its instance. The fPar will be disabled (enter a spinloop) because it cannot boot,
or if in vPars mode will return control to the monitor. Probable Cause: There is no
Memory owned by the soft partition (fPar) whose CPU emitted this event.
Recommended Action: Reconfigure the soft partition containing the CPU that emitted
this event and be sure to give memory resources to that soft partition before reset of
that partition. Until doing so, this soft partition will be unbootable and emit this
event on each attempt. WBEM EventID: 4708. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10936