HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 27

LBA has unexpected number of I/O Slots. Probable Cause: Unsupported I/O

Page 27 highlights

Event ID Event Severity 5507 Error 5509 Error 5510 Warning 5511 Error 5514 Error 5515 Error 5518 Warning 5521 Error 5525 Warning 5527 Error 5528 Error 5529 Error 5530 Warning 5546 Error 5547 Error Event Description An error was encountered communicating with utilities during PD rendez. Probable Cause: Verify communications with the utilities system. WBEM EventID: 413. WBEM ProviderName: FPL_IndicationProvider. Forward Progress is stopping. The Cell or System will not boot further. Probable Cause: An error occurred which triggered system firmware to cease making forward progress. The CPU is put into a spin loop so that external debugging can take place. See earlier event ids to help determine the cause of the error. Also note that the Error Response Mode is likely to have directed firmware to HALT. WBEM EventID: 414. WBEM ProviderName: FPL_IndicationProvider. No console is available for the DUI to use. Probable Cause: DUI was entered before the console is available. DUI will exit and processing will continue. WBEM EventID: 415. WBEM ProviderName: FPL_IndicationProvider. Error Processing encountered an unrecoverable error. Probable Cause: Decode the ASCII message and correct the problem. WBEM EventID: 416. WBEM ProviderName: FPL_IndicationProvider. System is unable to complete the Reset For Reconfiguration request. Probable Cause: Delay the request for reconfiguration until after the PD has been released from Sinc BIB. WBEM EventID: 417. WBEM ProviderName: FPL_IndicationProvider. The cell is not able to reach all requested cells through the fabric. Probable Cause: Fabric wasn't able to route to all cells described in the complex profile correctly due to a hardware problem. Some of the cells are unreachable. Update the complex profile or correct the hardware problem. WBEM EventID: 418. WBEM ProviderName: FPL_IndicationProvider. LBA has unexpected number of I/O Slots. Probable Cause: Unsupported I/O configuration. Recommended Action: Remove the I/O cards below the specified PCI-to-PCI bridge. WBEM EventID: 419. WBEM ProviderName: FPL_IndicationProvider. Console device failed to connect. Probable Cause: Debugging event, not for release. WBEM EventID: 420. WBEM ProviderName: FPL_IndicationProvider. Copying memory test code failed. Probable Cause: Memory test code located in main memory has been corrupted Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 421. WBEM ProviderName: FPL_IndicationProvider. A remote cell is in an unknown state of PD rendezvous. Probable Cause: Reset the PD. WBEM EventID: 2430. WBEM ProviderName: FPL_IndicationProvider. Multiple Core Cells have been discovered in the same PD. Probable Cause: Verify that the complex profile is correct and reset the partition. WBEM EventID: 423. WBEM ProviderName: FPL_IndicationProvider. The utilities component encountered an error when sending a command to the MP. Probable Cause: Verify the utilities system is connected correctly and reset. WBEM EventID: 424. WBEM ProviderName: FPL_IndicationProvider. Error received after issuing the Retrieve Cell Slot State command. Probable Cause: Make sure the GSP is connected and reset. WBEM EventID: 1007. WBEM ProviderName: FPL_IndicationProvider. This indicates that all the cpus in the cell did not rendezvous during the MCA. Probable Cause: When this happens the cell will step through some of the error logging code on its own and then reset itself. WBEM EventID: 426. WBEM ProviderName: FPL_IndicationProvider. This indicates that it does not have any access to the PD. Probable Cause: Forward Progress indicator; the cell will independently step through the error logging steps before it resets itself. WBEM EventID: 427. WBEM ProviderName: FPL_IndicationProvider. Platform Events 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
An error was encountered communicating with utilities during PD rendez. Probable
Cause: Verify communications with the utilities system. WBEM EventID: 413. WBEM
ProviderName: FPL_IndicationProvider.
Error
5507
Forward Progress is stopping. The Cell or System will not boot further. Probable
Cause: An error occurred which triggered system firmware to cease making forward
progress. The CPU is put into a spin loop so that external debugging can take place.
See earlier event ids to help determine the cause of the error. Also note that the Error
Response Mode is likely to have directed firmware to HALT. WBEM EventID: 414.
WBEM ProviderName: FPL_IndicationProvider.
Error
5509
No console is available for the DUI to use. Probable Cause: DUI was entered before
the console is available. DUI will exit and processing will continue. WBEM EventID:
415. WBEM ProviderName: FPL_IndicationProvider.
Warning
5510
Error Processing encountered an unrecoverable error. Probable Cause: Decode the
ASCII message and correct the problem. WBEM EventID: 416. WBEM ProviderName:
FPL_IndicationProvider.
Error
5511
System is unable to complete the Reset For Reconfiguration request. Probable Cause:
Delay the request for reconfiguration until after the PD has been released from Sinc
BIB. WBEM EventID: 417. WBEM ProviderName: FPL_IndicationProvider.
Error
5514
The cell is not able to reach all requested cells through the fabric. Probable Cause:
Fabric wasn't able to route to all cells described in the complex profile correctly due
to a hardware problem. Some of the cells are unreachable. Update the complex profile
or correct the hardware problem. WBEM EventID: 418. WBEM ProviderName:
FPL_IndicationProvider.
Error
5515
LBA has unexpected number of I/O Slots. Probable Cause: Unsupported I/O
configuration. Recommended Action: Remove the I/O cards below the specified
PCI-to-PCI bridge. WBEM EventID: 419. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5518
Console device failed to connect. Probable Cause: Debugging event, not for release.
WBEM EventID: 420. WBEM ProviderName: FPL_IndicationProvider.
Error
5521
Copying memory test code failed. Probable Cause: Memory test code located in main
memory has been corrupted Recommended Action: Contact HP support personnel
to troubleshoot the problem. WBEM EventID: 421. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5525
A remote cell is in an unknown state of PD rendezvous. Probable Cause: Reset the
PD. WBEM EventID: 2430. WBEM ProviderName: FPL_IndicationProvider.
Error
5527
Multiple Core Cells have been discovered in the same PD. Probable Cause: Verify
that the complex profile is correct and reset the partition. WBEM EventID: 423. WBEM
ProviderName: FPL_IndicationProvider.
Error
5528
The utilities component encountered an error when sending a command to the MP.
Probable Cause: Verify the utilities system is connected correctly and reset. WBEM
EventID: 424. WBEM ProviderName: FPL_IndicationProvider.
Error
5529
Error received after issuing the Retrieve Cell Slot State command. Probable Cause:
Make sure the GSP is connected and reset. WBEM EventID: 1007. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5530
This indicates that all the cpus in the cell did not rendezvous during the MCA.
Probable Cause: When this happens the cell will step through some of the error
logging code on its own and then reset itself. WBEM EventID: 426. WBEM
ProviderName: FPL_IndicationProvider.
Error
5546
This indicates that it does not have any access to the PD. Probable Cause: Forward
Progress indicator; the cell will independently step through the error logging steps
before it resets itself. WBEM EventID: 427. WBEM ProviderName:
FPL_IndicationProvider.
Error
5547
Platform Events
27