Event ID Event Severity Event Description 6 Information A SCSI physical drive with a status of OK that was located in the system has been removed. 7 Information A SCSI physical drive with a status of Error that was located in the system has been removed. 8 Error A SCSI physical drive status is now set to Predictive Failure. 9 Information A SCSI physical drive with a status of Predictive Failure that was located in the system has been removed. 10 Error A SCSI physical drive is offline and can no longer return data. No further status is available. 11 Information A SCSI physical drive that was located in the system and had a status of offline has been removed. 301 Error A Storage Enclosure Power Supply status has changed to non-redundant. 302 Information A Storage Enclosure Power Supply has changed to Fully Redundant. 303 Warning A Storage Enclosure Power Supply status has changed to Degraded Redundancy. 304 Information The storage enclosure fan subsystem is operating properly. 305 Warning A fan has failed, but there are enough fans in the fan subsystem to keep the enclosure cool. 306 Error A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool. 307 Information A Storage Enclosure Temperature sensor status changed from non-OK to OK. 308 Warning A Storage Enclosure Temperature sensor Status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. 309 Error A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. HP Smart Array Events Source in Windows Event Log: HP Smart Array Event ID Event Severity Event Description 1 Warning A Smart Array controller status has changed from non-OK to OK. 2 Error A Smart Array controller status has changed to Error. 3 Warning A Smart Array controller redundancy state has changed from Standby to Active. 4 Warning A Smart Array controller has detected that redundancy has been lost due to failure or loss of communication with partner controller. 5 Information Controller has detected that Redundancy has been restored and can communicate with partner controller. 6 Information A Smart Array controller Battery status has changed from non-OK to OK. 7 Warning A Smart Array controller Battery status has changed to Not Fully Charged. 8 Error A Smart Array controller battery status changed to Failed. 9 Information A Smart Array controller Cache status has changed from non-OK to OK. 108 WBEM Provider Event Tables