New for MtWhatever: BOOT_BAD_CPU_ORDER. Probable Cause: Check CPU load
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Event ID Event Severity 9041 Warning 9042 Warning 9043 Warning 9045 Warning 9046 Warning 9047 Warning 9049 Warning 9051 Warning 9052 Warning 9084 Error 9364 Warning 9365 Warning 9367 Warning Event Description Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really could have. Recommended Action: Upgrade PDC if this is found to be the problem and a new PDC image is available. WBEM EventID: 898. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really could have. Recommended Action: Upgrade PDC if this is found to be the problem and a new PDC image is available. WBEM EventID: 899. WBEM ProviderName: FPL_IndicationProvider. A reset for reconfiguration will be performed soon on the cell. Probable Cause: An error during cell initialization occurred and the cell will not be able to join the partition. Look for other errors in the event log that articulate the exact problem. WBEM EventID: 900. WBEM ProviderName: FPL_IndicationProvider. The Partition Profile specifies the wrong architecture type. Probable Cause: This is caused by the wrong type of complex profile being loaded. System firmware will default a new partition profile and continue on. WBEM EventID: 901. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable Cause: Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the concorde or CPU chips. Recommended Action: Troubleshoot the cell and either fix cell or replace the cell board. WBEM EventID: 902. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable Cause: PDC problem such that PDC is passing bad data from one function to another. Recommended Action: Upgrade PDC. WBEM EventID: 903. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition about to be reset because PDC is unable to access CPU data. Probable Cause: Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the concorde or CPU chips. Recommended Action: Troubleshoot the cell and either fix cell or replace the cell board. WBEM EventID: 904. WBEM ProviderName: FPL_IndicationProvider. Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable Cause: PDC problem such that PDC is passing bad data from one function to another. Recommended Action: Upgrade PDC. WBEM EventID: 905. WBEM ProviderName: FPL_IndicationProvider. PDC is unable to branch to other software via the Page Zero location. Probable Cause: The MEM_RENDEZ fields of Page Zero were programmed incorrectly. Recommended Action: Upgrade or patch the OS. WBEM EventID: 906. WBEM ProviderName: FPL_IndicationProvider. New for MtWhatever: BOOT_BAD_CPU_ORDER. Probable Cause: Check CPU load ordering. WBEM EventID: 2686. WBEM ProviderName: FPL_IndicationProvider. PDC couldn't access a data structure in PDH memory. Probable Cause: PDC bug in which PDC is trying to access PDH memory of a cell not in its partition. Recommended Action: Upgrade PDC if there is a version of PDC that fixes such a problem. WBEM EventID: 908. WBEM ProviderName: FPL_IndicationProvider. PDC couldn't access a data structure in PDH memory. Probable Cause: Hardware problem with the CPU or cell board. Recommended Action: Contact HP Support to confirm the CPUs and cell board are functioning properly. WBEM EventID: 909. WBEM ProviderName: FPL_IndicationProvider. Cell about to be halted because PDC couldn't determine relocated address of code. Probable Cause: Cell was unable to access its own PDH memory. Recommended Action: Troubleshoot the cell board and replace it if necessary. WBEM EventID: 910. WBEM ProviderName: FPL_IndicationProvider. Platform Events 61