HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 37

Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible

Page 37 highlights

Event ID Event Severity 5786 Warning 5787 Warning 5788 Error 5790 Warning 5791 Error 5793 Error 5794 Error 5795 Warning 5796 Warning 5797 Error 5798 Error 5799 Error 5800 Error 5802 Error Event Description EFI detected invalid internal privilege level. Probable Cause: SAL storage corrupted. Recommended Action: Reboot system. WBEM EventID: 522. WBEM ProviderName: FPL_IndicationProvider. EFI detected invalid privilege level when setting password. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM ProviderName: FPL_IndicationProvider. EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is invalid. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 524. WBEM ProviderName: FPL_IndicationProvider. Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio that is incompatible with the FSB frequency set in the chipset. Recommended Action: Contact your HP representative for support. WBEM EventID: 525. WBEM ProviderName: FPL_IndicationProvider. All processors slated for compatibility deconfiguration. Probable Cause: The user or SFW has set all CPUs to be deconfigured. Recommended Action: Look for events indicating incompatible or bad CPUs and replace them. If problem persists contact your HP representative for support. WBEM EventID: 526. WBEM ProviderName: FPL_IndicationProvider. An unexpected or invalid value was read from a crossbar remote route table. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PDCheck the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 527. WBEM ProviderName: FPL_IndicationProvider. Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible bad link, crossbar, or cell connection. Recommended Action: Check crossbar and link specified in the event data. Reset cell. WBEM EventID: 528. WBEM ProviderName: FPL_IndicationProvider. memory DIMM quad mis-match. Probable Cause: The user installed a mismatched quad of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in quads of DIMMs that are the same size and DRAM width. WBEM EventID: 529. WBEM ProviderName: FPL_IndicationProvider. Firmware detected excessive errors on the DIMM. Probable Cause: Firmware detected excessive errors on the DIMM / Replace the specified DIMM. WBEM EventID: 530. WBEM ProviderName: FPL_IndicationProvider. The OE (output enable) bit was not set for a XBC port. Probable Cause: Possible firmware or link error. Recommended Action: Check XBC and port specified by event data. WBEM EventID: 531. WBEM ProviderName: FPL_IndicationProvider. An error occurred while trying to read the PORT_STATUS CSR for a XBC port. Probable Cause: Possible bad connection between cell and backplane. Recommended Action: Check for hardware errors. Reset cell. WBEM EventID: 532. WBEM ProviderName: FPL_IndicationProvider. A XBC port was unexpectedly found to be landmined. Probable Cause: No action required. WBEM EventID: 533. WBEM ProviderName: FPL_IndicationProvider. CPUs running at different speeds were detected during rendezvous. Probable Cause: Reconfigure the PD so that all cells have processors running at the same speed. WBEM EventID: 1016. WBEM ProviderName: FPL_IndicationProvider. The link between the local CC and the local XBC is unexpectedly not initialized. Probable Cause: An error initializing fabric Recommended Action: A previously reported event may provide exact detailsReboot, if failure persists, then either replace the CC chip or the system backplane. WBEM EventID: 535. WBEM ProviderName: FPL_IndicationProvider. Platform Events 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
EFI detected invalid internal privilege level. Probable Cause: SAL storage corrupted.
Recommended Action: Reboot system. WBEM EventID: 522. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5786
EFI detected invalid privilege level when setting password. Probable Cause: Internal
EFI error. Recommended Action: Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5787
EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is
invalid. Recommended Action: Reboot or update System FW. If problem persists
contact your HP representative for support. WBEM EventID: 524. WBEM
ProviderName: FPL_IndicationProvider.
Error
5788
Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio
that is incompatible with the FSB frequency set in the chipset. Recommended Action:
Contact your HP representative for support. WBEM EventID: 525. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5790
All processors slated for compatibility deconfiguration. Probable Cause: The user or
SFW has set all CPUs to be deconfigured. Recommended Action: Look for events
indicating incompatible or bad CPUs and replace them. If problem persists contact
your HP representative for support. WBEM EventID: 526. WBEM ProviderName:
FPL_IndicationProvider.
Error
5791
An unexpected or invalid value was read from a crossbar remote route table. Probable
Cause: An XBC is indicating a port failure Recommended Action: Validate all of the
cells connectivity to the PDCheck the XBC chips seating reset the system replace
either cells/system backplane. WBEM EventID: 527. WBEM ProviderName:
FPL_IndicationProvider.
Error
5793
Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible
bad link, crossbar, or cell connection. Recommended Action: Check crossbar and link
specified in the event data. Reset cell. WBEM EventID: 528. WBEM ProviderName:
FPL_IndicationProvider.
Error
5794
memory DIMM quad mis-match. Probable Cause: The user installed a mismatched
quad of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in quads of DIMMs that are the same
size and DRAM width. WBEM EventID: 529. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5795
Firmware detected excessive errors on the DIMM. Probable Cause: Firmware detected
excessive errors on the DIMM / Replace the specified DIMM. WBEM EventID: 530.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5796
The OE (output enable) bit was not set for a XBC port. Probable Cause: Possible
firmware or link error. Recommended Action: Check XBC and port specified by event
data. WBEM EventID: 531. WBEM ProviderName: FPL_IndicationProvider.
Error
5797
An error occurred while trying to read the PORT_STATUS CSR for a XBC port.
Probable Cause: Possible bad connection between cell and backplane. Recommended
Action: Check for hardware errors. Reset cell. WBEM EventID: 532. WBEM
ProviderName: FPL_IndicationProvider.
Error
5798
A XBC port was unexpectedly found to be landmined. Probable Cause: No action
required. WBEM EventID: 533. WBEM ProviderName: FPL_IndicationProvider.
Error
5799
CPUs running at different speeds were detected during rendezvous. Probable Cause:
Reconfigure the PD so that all cells have processors running at the same speed. WBEM
EventID: 1016. WBEM ProviderName: FPL_IndicationProvider.
Error
5800
The link between the local CC and the local XBC is unexpectedly not initialized.
Probable Cause: An error initializing fabric Recommended Action: A previously
reported event may provide exact detailsReboot, if failure persists, then either replace
the CC chip or the system backplane. WBEM EventID: 535. WBEM ProviderName:
FPL_IndicationProvider.
Error
5802
Platform Events
37