HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 77
your HP Support Representative to analyze the fabric. WBEM EventID: 2943. WBEM
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
Event ID Event Severity 10398 Warning 10401 Warning 10402 Warning 10403 Warning 10404 Warning 10405 Warning 10406 Warning 10407 Warning 10408 Warning 10409 Warning Event Description An XBC port was found with an unexpected neighbor chip. Data field: expected chip type | (actual chip type 32). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2940. WBEM ProviderName: FPL_IndicationProvider. A cell/port pair was not found in the expected graph data. Data field: (cellNum 32) | CC portNum. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2942. WBEM ProviderName: FPL_IndicationProvider. Arches Fabric Traversability code unexpectedly found the local cell link not connected. Data field: linkState (0 = connected, 1 = link pending, 2 = not connected, -1 = error). Probable Cause: A previously healthy link was found to have fatal errors. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2943. WBEM ProviderName: FPL_IndicationProvider. Error reading the ROUTEx CSR on the XBC. Data field: route index | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2944. WBEM ProviderName: FPL_IndicationProvider. Unable to read the ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2945. WBEM ProviderName: FPL_IndicationProvider. An XBC port has an unexpected neighbor chip type. Data field: expected neighbor chip type | (actual neighbor chip type 32). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2946. WBEM ProviderName: FPL_IndicationProvider. A Cell-Cell link has an unexpected neighbor chip type. Data field: expected neighbor chip type | (actual neighbor chip type 32). Probable Cause: System firmware has found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2947. WBEM ProviderName: FPL_IndicationProvider. The cell/port pair does not exist in the Arches Fabric expected graph data. Data field: CC port | (cellNum 32). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2948. WBEM ProviderName: FPL_IndicationProvider. A Cell-Cell link is connected to an unexpected neighbor port. Data field: expected neighbor port | (actual neighbor port 32). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2949. WBEM ProviderName: FPL_IndicationProvider. A Cell-Cell link is connected to an unexpected cell. Data field: expected neighbor ID | (actual neighbor ID 16) | (target cell 32) | (local cell 48). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2950. WBEM ProviderName: FPL_IndicationProvider. Platform Events 77