HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 38
Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Event ID Event Severity 5803 Error 5804 Error 5805 Warning 5806 Error 5807 Error 5808 Error 5809 Error 5810 Error 5811 Warning 5812 Warning 5813 Error 5823 Warning 5824 Error 5825 Warning 5827 Warning 5832 Warning Event Description An invalid XBC number was given. Probable Cause: Firmware error Recommended Action: Reset cell. WBEM EventID: 536. WBEM ProviderName: FPL_IndicationProvider. An invalid XBC port number was given. Probable Cause: Firmware error Recommended Action: Reset cell. WBEM EventID: 537. WBEM ProviderName: FPL_IndicationProvider. A bad parameter was passed to the LED function in the utilities component. Probable Cause: Contact FW engineering. This is a bug. WBEM EventID: 2464. WBEM ProviderName: FPL_IndicationProvider. An unexpected neighbor type was read from a XBC PORT_NEIGHBOR_INFO CSR. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. WBEM EventID: 539. WBEM ProviderName: FPL_IndicationProvider. A given XBC port is not a valid XBC-CC port. Probable Cause: Firmware error. Recommended Action: Reset cell. WBEM EventID: 540. WBEM ProviderName: FPL_IndicationProvider. A XBC port was unexpectedly found to be an invalid XBC-XBC port. Probable Cause: Firmware error. Recommended Action: Reset cell. WBEM EventID: 541. WBEM ProviderName: FPL_IndicationProvider. The XBC neighbor chip number does not match the expected value for this topology. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. WBEM EventID: 542. WBEM ProviderName: FPL_IndicationProvider. The XBC neighbor port number does not match the expected value for this topology. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. WBEM EventID: 543. WBEM ProviderName: FPL_IndicationProvider. Write through to BMC token failed. Probable Cause: Problem accessing the BMC. Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If problem persists, contact your HP representative for support. WBEM EventID: 544. WBEM ProviderName: FPL_IndicationProvider. Utilities reported an error while trying to manipulate the LED. Probable Cause: It is likely the GSP is not present or the device specified is not present. Solve these problems and try again. WBEM EventID: 2465. WBEM ProviderName: FPL_IndicationProvider. Duplicate Cpu Ids were detected within a cell. Probable Cause: Most likely cause is a bad cpu module connection on the cell board. Replace the cell board. WBEM EventID: 546. WBEM ProviderName: FPL_IndicationProvider. OS crashdump started (D700). Probable Cause: panic occurred. WBEM EventID: 547. WBEM ProviderName: FPL_IndicationProvider. OS legacy PA hex fault code (Bxxx). Probable Cause: fault/panic. WBEM EventID: 548. WBEM ProviderName: FPL_IndicationProvider. OS dump status (EFxx). Probable Cause: panic, mca, or INIT path: attempt to write out the dump is complete Recommended Action: No action required. WBEM EventID: 549. WBEM ProviderName: FPL_IndicationProvider. Setting processor response timeout failed. Probable Cause: A PAL call made by SFW has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 550. WBEM ProviderName: FPL_IndicationProvider. Unable to validate blank password during EFI security initialization. Probable Cause: BMC failed. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP representative to check the BMC. WBEM EventID: 551. WBEM ProviderName: FPL_IndicationProvider. 38 WBEM Provider Event Tables