Server Provider (SysEvt) Events
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Event ID Event Severity Event Description 10 Information A Smart Array controller Cache status has changed to Temporarily Disabled. This may be caused by a rebuild or configuration change. Normal operation will return after background operations have completed. 11 Warning A Smart Array controller Cache status has changed to Permanently Disabled. The controller has detected a problem with the cache and has disabled the cache permanently. 101 Information A logical drive status has changed from a non-OK state to OK. 102 Error A logical drive status has changed to Error. 103 Warning A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost. 201 Information A physical drive status has changed from a non-OK state to OK. 202 Error A physical drive status has changed to Error. 203 Information A physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the RAID set. 204 Error A physical drive status has changed to Predictive Failure. 301 Warning A Storage Enclosure Power Subsystem status has changed to non-redundant. 302 Information A Storage Enclosure Power Supply has changed to Fully Redundant. 303 Warning A Storage Enclosure Power Supply status has changed to Degraded Redundancy. 304 Information A Storage Enclosure Fan status has changed from a non-OK state to OK. 305 Warning A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans. 306 Error A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. 307 Information A Storage Enclosure Temperature sensor status changed from non-OK to OK. 308 Warning A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. 309 Error A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. Server Provider (SysEvt) Events Source in Windows Event Log: HP System Event ID Event Severity Event Description 2001 Information HP Insight Management WBEM Providers have started. Server Provider (SysEvt) Events 109