HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 55

The Dillon IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Probable

Page 55 highlights

Event ID Event Severity 8757 Warning 8758 Warning 8761 Warning 8762 Warning 8763 Error 8768 Warning 8771 Warning 8772 Warning 8784 Warning 8787 Warning 8797 Error 8798 Warning 8806 Warning 8807 Warning Event Description failure on OLA cell during attempt to synch its real-time clock. Probable Cause: Couldn't communicate with OLA cell. Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID: 6956. WBEM ProviderName: FPL_IndicationProvider. SAL errlog access timeout. Probable Cause: Firmware is taking too long to process requests. WBEM EventID: 810. WBEM ProviderName: FPL_IndicationProvider. The Dillon IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Probable Cause: The PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 2442. WBEM ProviderName: FPL_IndicationProvider. Indicated the Dillon IPR is not cleared after a number of PDC attempts. Probable Cause: PDH FPGA IPR is not cleared after a number of PDC attempts. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 1759. WBEM ProviderName: FPL_IndicationProvider. failed accessing the core cell RTC while synchronizing the OLA cell's RTC. Probable Cause: Core cell data could not be accessed/fabric connections went bad Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID: 6957. WBEM ProviderName: FPL_IndicationProvider. The echelon given in the data field is not fully populated. Probable Cause: the specified echelon is not fully populated and is not usable Recommended Action: add or replace dimms in the specified echelon. WBEM EventID: 816. WBEM ProviderName: FPL_IndicationProvider. Attempted to read the port state from an illegal port number. Probable Cause: An invalid port number has been provided. The port number will be converted to an internal port and processing should continue. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 817. WBEM ProviderName: FPL_IndicationProvider. Attempted to write the port state for an illegal port. Probable Cause: An invalid port number has been provided. The port number will be converted to an internal port and processing should continue. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 818. WBEM ProviderName: FPL_IndicationProvider. The main backplane is reporting the LPM status as fault. Probable Cause: Many possible causes, repair / replace the appropriate part. WBEM EventID: 1760. WBEM ProviderName: FPL_IndicationProvider. The IO backplane is reporting a LPM status as fault. Probable Cause: Service / replace the appropriate part of, or the entire backplane. WBEM EventID: 1762. WBEM ProviderName: FPL_IndicationProvider. System firmware was unable to default the complex profile. Probable Cause: Needed information could not be obtained. Reset the MP. WBEM EventID: 822. WBEM ProviderName: FPL_IndicationProvider. Firmware could not set Pal Proc features. Probable Cause: FW MCA code uses this PAL_SET_PROC_FEATURES to escalate future MCA to BINIT. This event id when emitted during an MCA processing means that any subsequent global MCA would not cause all the processors in the PD to MCA again. WBEM EventID: 2443. WBEM ProviderName: FPL_IndicationProvider. Means that the error log space in the Nvram has not been allocated. Probable Cause: This happens because of the NVRAM is full with unconsumed error logs. Clear the error logs. WBEM EventID: 824. WBEM ProviderName: FPL_IndicationProvider. This indicates the maximum number of logs for the event. Probable Cause: This shouldn't be occur. But in case it does than clear the error logs of this event type from the nvram. WBEM EventID: 825. WBEM ProviderName: FPL_IndicationProvider. Platform Events 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
failure on OLA cell during attempt to synch its real-time clock. Probable Cause:
Couldn't communicate with OLA cell. Recommended Action: Collect IPMI events
and contact HP Support. WBEM EventID: 6956. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8757
SAL errlog access timeout. Probable Cause: Firmware is taking too long to process
requests. WBEM EventID: 810. WBEM ProviderName: FPL_IndicationProvider.
Warning
8758
The Dillon IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Probable
Cause: The PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a
cell. Recommended Action: Contact HP Support personnel to troubleshoot the
problem. WBEM EventID: 2442. WBEM ProviderName: FPL_IndicationProvider.
Warning
8761
Indicated the Dillon IPR is not cleared after a number of PDC attempts. Probable
Cause: PDH FPGA IPR is not cleared after a number of PDC attempts. Recommended
Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID:
1759. WBEM ProviderName: FPL_IndicationProvider.
Warning
8762
failed accessing the core cell RTC while synchronizing the OLA cell's RTC. Probable
Cause: Core cell data could not be accessed/fabric connections went bad
Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID:
6957. WBEM ProviderName: FPL_IndicationProvider.
Error
8763
The echelon given in the data field is not fully populated. Probable Cause: the specified
echelon is not fully populated and is not usable Recommended Action: add or replace
dimms in the specified echelon. WBEM EventID: 816. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8768
Attempted to read the port state from an illegal port number. Probable Cause: An
invalid port number has been provided. The port number will be converted to an
internal port and processing should continue. Recommended Action: Contact HP
Support personnel to analyze the fabric. WBEM EventID: 817. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8771
Attempted to write the port state for an illegal port. Probable Cause: An invalid port
number has been provided. The port number will be converted to an internal port
and processing should continue. Recommended Action: Contact HP Support personnel
to analyze the fabric. WBEM EventID: 818. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8772
The main backplane is reporting the LPM status as fault. Probable Cause: Many
possible causes, repair / replace the appropriate part. WBEM EventID: 1760. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8784
The IO backplane is reporting a LPM status as fault. Probable Cause: Service / replace
the appropriate part of, or the entire backplane. WBEM EventID: 1762. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8787
System firmware was unable to default the complex profile. Probable Cause: Needed
information could not be obtained. Reset the MP. WBEM EventID: 822. WBEM
ProviderName: FPL_IndicationProvider.
Error
8797
Firmware could not set Pal Proc features. Probable Cause: FW MCA code uses this
PAL_SET_PROC_FEATURES to escalate future MCA to BINIT. This event id when
emitted during an MCA processing means that any subsequent global MCA would
not cause all the processors in the PD to MCA again. WBEM EventID: 2443. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8798
Means that the error log space in the Nvram has not been allocated. Probable Cause:
This happens because of the NVRAM is full with unconsumed error logs. Clear the
error logs. WBEM EventID: 824. WBEM ProviderName: FPL_IndicationProvider.
Warning
8806
This indicates the maximum number of logs for the event. Probable Cause: This
shouldn't be occur. But in case it does than clear the error logs of this event type from
the nvram. WBEM EventID: 825. WBEM ProviderName: FPL_IndicationProvider.
Warning
8807
Platform Events
55