from being chosen. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return

Page 87 highlights

Event ID Event Severity 11033 Warning 11034 Warning 11038 Warning 11039 Warning 11040 Warning 11041 Warning 11042 Warning 11052 Warning 11452 Error 11454 Error 11456 Error Event Description Unable to generate an ALB address in Arches Fabric ArfSetDefaultCSRs() function. Data field:(cell number 56) | (port number 48) | (xbc ID 32) | (return value). Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4839. WBEM ProviderName: FPL_IndicationProvider. SetDefaultCSRs function failed unexpectedly. Arches Fabric was unable to set XBC CSRs to default values. Data field: return value from SetDefaultCSRs. Probable Cause: An error occurred while routing the fabric Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4840. WBEM ProviderName: FPL_IndicationProvider. A problem was encountered while routing which prevented an appropriate route from being chosen. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return status. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4871. WBEM ProviderName: FPL_IndicationProvider. An error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return status. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4872. WBEM ProviderName: FPL_IndicationProvider. An error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return status. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4873. WBEM ProviderName: FPL_IndicationProvider. An invalid port number was returned when selecting a route for the XBC-CC link. Data Field: (destination cell 56) | (xbc port 44) | (xbc # 32) | port selected. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. An error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | switch fabric. Probable Cause: An error occurred while routing the fabric Recommended Action: Contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4875. WBEM ProviderName: FPL_IndicationProvider. The second flash part is not programmed with a valid image. WBEM EventID: 7212. WBEM ProviderName: FPL_IndicationProvider. System backplane power has reported a 1.2v LDO fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 1.2v LDO fault. Recommended Action: Check system backplane. WBEM EventID: 4906. WBEM ProviderName: FPL_IndicationProvider. System backplane power has reported a 2.5v LDO fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 2.5v LDO fault. Recommended Action: Check system backplane. WBEM EventID: 4907. WBEM ProviderName: FPL_IndicationProvider. System backplane power has reported a 3.3v house keeping power fault. The data field contains the physical location of the fault. Probable Cause: System backplane power board has reported a 3.3v house keeping fault. Recommended Action: Check system backplane power board. WBEM EventID: 4908. WBEM ProviderName: FPL_IndicationProvider. Platform Events 87

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Unable to generate an ALB address in Arches Fabric ArfSetDefaultCSRs() function.
Data field:(cell number 56) | (port number 48) | (xbc ID 32) | (return value). Probable
Cause: An error occurred while routing the fabric, possible data corruption or
firmware error. Recommended Action: Contact your HP support representative to
inspect the fabric and system firmware. WBEM EventID: 4839. WBEM ProviderName:
FPL_IndicationProvider.
Warning
11033
SetDefaultCSRs function failed unexpectedly. Arches Fabric was unable to set XBC
CSRs to default values. Data field: return value from SetDefaultCSRs. Probable Cause:
An error occurred while routing the fabric Recommended Action: Collect IPMI event
logs, and contact your HP support representative to inspect the fabric and system
firmware. WBEM EventID: 4840. WBEM ProviderName: FPL_IndicationProvider.
Warning
11034
A problem was encountered while routing which prevented an appropriate route
from being chosen. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32 | return
status. Probable Cause: An error occurred while routing the fabric Recommended
Action: Contact your HP support representative to inspect the fabric and system
firmware. WBEM EventID: 4871. WBEM ProviderName: FPL_IndicationProvider.
Warning
11038
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| return status. Probable Cause: An error occurred while routing the fabric
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. WBEM EventID: 4872. WBEM ProviderName:
FPL_IndicationProvider.
Warning
11039
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| return status. Probable Cause: An error occurred while routing the fabric
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. WBEM EventID: 4873. WBEM ProviderName:
FPL_IndicationProvider.
Warning
11040
An invalid port number was returned when selecting a route for the XBC-CC link.
Data Field: (destination cell 56) | (xbc port 44) | (xbc # 32) | port selected. Probable
Cause: An error occurred while routing the fabric Recommended Action: Contact
your HP support representative to inspect the fabric and system firmware.
Warning
11041
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| switch fabric. Probable Cause: An error occurred while routing the fabric
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. WBEM EventID: 4875. WBEM ProviderName:
FPL_IndicationProvider.
Warning
11042
The second flash part is not programmed with a valid image. WBEM EventID: 7212.
WBEM ProviderName: FPL_IndicationProvider.
Warning
11052
System backplane power has reported a 1.2v LDO fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 1.2v LDO fault. Recommended Action: Check system backplane. WBEM
EventID: 4906. WBEM ProviderName: FPL_IndicationProvider.
Error
11452
System backplane power has reported a 2.5v LDO fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 2.5v LDO fault. Recommended Action: Check system backplane. WBEM
EventID: 4907. WBEM ProviderName: FPL_IndicationProvider.
Error
11454
System backplane power has reported a 3.3v house keeping power fault. The data
field contains the physical location of the fault. Probable Cause: System backplane
power board has reported a 3.3v house keeping fault. Recommended Action: Check
system backplane power board. WBEM EventID: 4908. WBEM ProviderName:
FPL_IndicationProvider.
Error
11456
Platform Events