HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 78
In SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
Event ID Event Severity 10412 Warning 10413 Warning 10414 Warning 10415 Warning 10427 Warning 10429 Warning 10431 Warning 10432 Warning 10435 Warning 10436 Warning Event Description An EFI driver failed to load. Probable Cause: A reflashable EFI Driver has failed a checksum test. Recommended Action: Reflash the system firmware to correct this error. WBEM EventID: 6852. WBEM ProviderName: FPL_IndicationProvider. VM_FindAllRoutes returned an unexpected error during Non-Coherent table setup. Data field: (return value) | (source cell 32) | (target cell 48). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2951. WBEM ProviderName: FPL_IndicationProvider. In SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data field: (data written to CSR) | (actual CSR data read 32). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2952. WBEM ProviderName: FPL_IndicationProvider. SetupNCTable failed in ArfPhase3. Data field: cell set passed in to SetupNCTable. Probable Cause: System firmware was unable to write some fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2953. WBEM ProviderName: FPL_IndicationProvider. A failure occurred while prepping a back-to-back system for post-rendezvous Arches Fabric setup. Data field: return value from Phase4BackToBackPrep. Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2954. WBEM ProviderName: FPL_IndicationProvider. ArfPhase4 was unable to set up the Non-Coherent link select to at least one cell in its alive/gsm sharing set. Data field: bitmap of unreachable cells. Probable Cause: System firmware was unable to find valid routes to each cell in a previously good partition. Possible cable/connection problems. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2955. WBEM ProviderName: FPL_IndicationProvider. Unable to set the Non-Coherent route. Data field: (sourceCell 32) | (cell set passed in to SetupNCTable). Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2956. WBEM ProviderName: FPL_IndicationProvider. Unable to setup the Coherent route table for a cell in our partition. Data field: (sourceCell 32) | (cell set passed in to SetupCohTable). Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2957. WBEM ProviderName: FPL_IndicationProvider. Error writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (route set to disable) | (xbcNum 32) | (xbc port 48). Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2958. WBEM ProviderName: FPL_IndicationProvider. The Arches Fabric vertex module returned an unexpected error during Non-Coherent table setup. Data field: (return value) | (sourceCell 32) | (dest cell 48). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2959. WBEM ProviderName: FPL_IndicationProvider. 78 WBEM Provider Event Tables