Incompatible I/O Backplane or I/O cables installed. Probable Cause: Incorrect I/O
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Event ID Event Severity 10619 Warning 10620 Warning 10621 Warning 10622 Warning 10623 Warning 10625 Warning 10626 Warning 10628 Warning 10629 Error 10698 Warning 10702 Error Event Description VM_DeleteVertex() failed in SynchGraphs(). Data field: (vertex id 32) | (vertex type 56) | (return value from VM_DeleteVertex()). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4525. WBEM ProviderName: FPL_IndicationProvider. VM_DeleteEdge() failed in the Arches Fabric function SynchGraphs(). Data field:(vertex id1 32) | (vertex port1 48) | (vertex type1 56) | (vertex id2 0) | (vertex port2 16) | (vertex type2 24). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4526. WBEM ProviderName: FPL_IndicationProvider. Unexpected error when calling an Arches Fabric vertex module function. Data field: return value from vertex module function. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4527. WBEM ProviderName: FPL_IndicationProvider. Unexpected return from an Arches Fabric vertex module function while copying a cell's graph. Data field: return value from vertex module function. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4528. WBEM ProviderName: FPL_IndicationProvider. The checksum update for the PDT has failed. Probable Cause: The call to update the checksum for the PDT failed. The PDT will most likely be cleared upon reboot. Recommended Action: Reboot Upgrade SFW Contact HP support. WBEM EventID: 4529. WBEM ProviderName: FPL_IndicationProvider. The checksum in the memory area of NVM is bad. Probable Cause: The checksum in the memory area of NVM is bad. Recommended Action: Upgrade SFW Contact HP support. WBEM EventID: 4530. WBEM ProviderName: FPL_IndicationProvider. Checksum calculation failed. Probable Cause: The checksum calculation failed. The data field contains the address that the checksum calculation was attempted on. Recommended Action: Upgrade SFW Contact HP support. WBEM EventID: 4531. WBEM ProviderName: FPL_IndicationProvider. Both SAL's copy and BMC copy of the token specified in the data field is bad. Probable Cause: Both SAL's copy and BMC copy of the token specified in the data field is bad. SFW is reinitializing that token to it's default value Recommended Action: Verify that the default settings are appropriate. For example, run the EFI baud and boot test command. WBEM EventID: 4532. WBEM ProviderName: FPL_IndicationProvider. Incompatible I/O Backplane or I/O cables installed. Probable Cause: Incorrect I/O backplane and/or I/O backplane cables are connected to the cell board. The cell board is not compatible with I/O backplane and/or I/O backplane cables. Recommended Action: Remove I/O backplane and/or I/O backplane cables and replace with compatible I/O backplane and/or I/O backplane cables. WBEM EventID: 4533. WBEM ProviderName: FPL_IndicationProvider. The fPar identified by the event detail will be unusable. Probable Cause: Firmware ran out of NVRAM before the server completed cold boot initialization. Recommended Action: Initialize the NVRAM to the factory defaults and reset the server. Soft partitions will have to be recreated from scratch before they are available. WBEM EventID: 4667. WBEM ProviderName: FPL_IndicationProvider. Firmware is out of NVRAM and cannot built the ILM memory slice device map. Probable Cause: Firmware ran out of NVRAM before the server completed cold boot initialization. Recommended Action: Initialize the NVRAM to the factory defaults and reset the server. Soft partitions will have to be recreated from scratch before they are available. WBEM EventID: 4671. WBEM ProviderName: FPL_IndicationProvider. 82 WBEM Provider Event Tables