HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 13

CPU failed late selftest. Probable Cause: For ZX1 systems, a Correctable Single Bit

Page 13 highlights

Event ID Event Severity 5010 Error 5011 Error 5013 Warning 5023 Error 5025 Error 5027 Error 5028 Error 5030 Warning 5031 Warning 5033 Warning 5034 Warning 5036 Warning 5037 Warning Event Description Boot cell launch EFI failure. Probable Cause: The system has failed to launch EFI because of an internal error. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 203. WBEM ProviderName: FPL_IndicationProvider. Monarch selection failure. Probable Cause: An internal error has caused monarch selection to fail. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 204. WBEM ProviderName: FPL_IndicationProvider. CPU monarch collision. Probable Cause: Unexpected error has occurred during monarch selection. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 205. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize EFI failure. Probable Cause: An internal error has occurred that prevented EFI from virtualizing. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 207. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize PAL failure. Probable Cause: SFW was unable to virtualize PAL. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 208. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize SAL failure. Probable Cause: SFW was unable to virtualize SAL. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 209. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize SALPROC failure. Probable Cause: SFW was unable to virtualize SALPROC. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 210. WBEM ProviderName: FPL_IndicationProvider. CPU struct init failed. Probable Cause: A CPU has failed the configuration process. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 211. WBEM ProviderName: FPL_IndicationProvider. CPU failed early config. Probable Cause: A CPU has failed the early configuration process. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 212. WBEM ProviderName: FPL_IndicationProvider. CPU failed early selftest. Probable Cause: A CPU has failed early self test. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 213. WBEM ProviderName: FPL_IndicationProvider. CPU failed. Probable Cause: A CPU has failed. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 214. WBEM ProviderName: FPL_IndicationProvider. CPU failed late selftest. Probable Cause: For ZX1 systems, a Correctable Single Bit Memory error has caused CPU late self test to fail. It is possible the CPU is not faulty in this case. For zx2 systems, the CPU has failed selftest. Recommended Action: Look for the event 'MEM_CORR_ERR' from the last time the system was running. If you find these events, replace that DIMM(s) before replacing the CPU's. Replace DIMMs with excessive 'MEM_CORR_ERR' first. If after replacing all suspect DIMMs this event is still seen, replace the CPU. Probable Cause: A CPU has failed. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 215. WBEM ProviderName: FPL_IndicationProvider. CPU not enough late test memory. Probable Cause: Insufficient memory. Recommended action: Increase memory and reboot. WBEM EventID: 216. WBEM ProviderName: FPL_IndicationProvider. Platform Events 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Boot cell launch EFI failure. Probable Cause: The system has failed to launch EFI
because of an internal error. Recommended Action: Reboot or update System FW. If
problem persists contact your HP representative for support. WBEM EventID: 203.
WBEM ProviderName: FPL_IndicationProvider.
Error
5010
Monarch selection failure. Probable Cause: An internal error has caused monarch
selection to fail. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 204. WBEM ProviderName:
FPL_IndicationProvider.
Error
5011
CPU monarch collision. Probable Cause: Unexpected error has occurred during
monarch selection. Recommended Action: Reboot, if problem persists contact your
HP representative for support. WBEM EventID: 205. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5013
Boot cell virtualize EFI failure. Probable Cause: An internal error has occurred that
prevented EFI from virtualizing. Recommended Action: Reboot, if problem persists
contact your HP representative for support. WBEM EventID: 207. WBEM
ProviderName: FPL_IndicationProvider.
Error
5023
Boot cell virtualize PAL failure. Probable Cause: SFW was unable to virtualize PAL.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 208. WBEM ProviderName: FPL_IndicationProvider.
Error
5025
Boot cell virtualize SAL failure. Probable Cause: SFW was unable to virtualize SAL.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 209. WBEM ProviderName: FPL_IndicationProvider.
Error
5027
Boot cell virtualize SALPROC failure. Probable Cause: SFW was unable to virtualize
SALPROC. Recommended Action: Reboot, if problem persists contact your HP
representative for support. WBEM EventID: 210. WBEM ProviderName:
FPL_IndicationProvider.
Error
5028
CPU struct init failed. Probable Cause: A CPU has failed the configuration process.
Recommended Action: Replace CPU. If problem persists contact your HP
representative for support. WBEM EventID: 211. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5030
CPU failed early config. Probable Cause: A CPU has failed the early configuration
process. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 212. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5031
CPU failed early selftest. Probable Cause: A CPU has failed early self test.
Recommended Action: Replace CPU. If problem persists contact your HP
representative for support. WBEM EventID: 213. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5033
CPU failed. Probable Cause: A CPU has failed. Recommended Action: Replace CPU.
If problem persists contact your HP representative for support. WBEM EventID: 214.
WBEM ProviderName: FPL_IndicationProvider.
Warning
5034
CPU failed late selftest. Probable Cause: For ZX1 systems, a Correctable Single Bit
Memory error has caused CPU late self test to fail. It is possible the CPU is not faulty
in this case. For zx2 systems, the CPU has failed selftest. Recommended Action: Look
for the event 'MEM_CORR_ERR' from the last time the system was running. If you
find these events, replace that DIMM(s) before replacing the CPU's. Replace DIMMs
with excessive 'MEM_CORR_ERR' first. If after replacing all suspect DIMMs this
event is still seen, replace the CPU. Probable Cause: A CPU has failed. Recommended
Action: Replace CPU. If problem persists contact your HP representative for support.
WBEM EventID: 215. WBEM ProviderName: FPL_IndicationProvider.
Warning
5036
CPU not enough late test memory. Probable Cause: Insufficient memory.
Recommended action: Increase memory and reboot. WBEM EventID: 216. WBEM
ProviderName: FPL_IndicationProvider.
Warning
5037
Platform Events