HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 13
CPU failed late selftest. Probable Cause: For ZX1 systems, a Correctable Single Bit
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Event ID Event Severity 5010 Error 5011 Error 5013 Warning 5023 Error 5025 Error 5027 Error 5028 Error 5030 Warning 5031 Warning 5033 Warning 5034 Warning 5036 Warning 5037 Warning Event Description Boot cell launch EFI failure. Probable Cause: The system has failed to launch EFI because of an internal error. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 203. WBEM ProviderName: FPL_IndicationProvider. Monarch selection failure. Probable Cause: An internal error has caused monarch selection to fail. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 204. WBEM ProviderName: FPL_IndicationProvider. CPU monarch collision. Probable Cause: Unexpected error has occurred during monarch selection. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 205. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize EFI failure. Probable Cause: An internal error has occurred that prevented EFI from virtualizing. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 207. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize PAL failure. Probable Cause: SFW was unable to virtualize PAL. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 208. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize SAL failure. Probable Cause: SFW was unable to virtualize SAL. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 209. WBEM ProviderName: FPL_IndicationProvider. Boot cell virtualize SALPROC failure. Probable Cause: SFW was unable to virtualize SALPROC. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 210. WBEM ProviderName: FPL_IndicationProvider. CPU struct init failed. Probable Cause: A CPU has failed the configuration process. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 211. WBEM ProviderName: FPL_IndicationProvider. CPU failed early config. Probable Cause: A CPU has failed the early configuration process. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 212. WBEM ProviderName: FPL_IndicationProvider. CPU failed early selftest. Probable Cause: A CPU has failed early self test. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 213. WBEM ProviderName: FPL_IndicationProvider. CPU failed. Probable Cause: A CPU has failed. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 214. WBEM ProviderName: FPL_IndicationProvider. CPU failed late selftest. Probable Cause: For ZX1 systems, a Correctable Single Bit Memory error has caused CPU late self test to fail. It is possible the CPU is not faulty in this case. For zx2 systems, the CPU has failed selftest. Recommended Action: Look for the event 'MEM_CORR_ERR' from the last time the system was running. If you find these events, replace that DIMM(s) before replacing the CPU's. Replace DIMMs with excessive 'MEM_CORR_ERR' first. If after replacing all suspect DIMMs this event is still seen, replace the CPU. Probable Cause: A CPU has failed. Recommended Action: Replace CPU. If problem persists contact your HP representative for support. WBEM EventID: 215. WBEM ProviderName: FPL_IndicationProvider. CPU not enough late test memory. Probable Cause: Insufficient memory. Recommended action: Increase memory and reboot. WBEM EventID: 216. WBEM ProviderName: FPL_IndicationProvider. Platform Events 13