System FW was unable to access the XBC semaphore. Probable Cause: System FW

Page 79 highlights

Event ID Event Severity 10439 Warning 10475 Warning 10481 Warning 10482 Warning 10483 Warning 10487 Warning 10489 Warning 10490 Warning 10495 Error 10509 Warning 10510 Warning 10516 Warning 10518 Warning Event Description A write to a Skyline Global LINK_SEL_COHx CSR failed. Data field: cell number of the Skyline that failed. Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2960. WBEM ProviderName: FPL_IndicationProvider. Unable to write the XBC port scratch CSR with the routing state. Data field: (routing state) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 2962. WBEM ProviderName: FPL_IndicationProvider. System Firmware was unable to access the configured set stored in the complex profile. Probable Cause: SFW was unable to access the configured set stored in the complex profile. Recommended Action: Collect IPMI events and contact your HP Support Representative. WBEM EventID: 6874. WBEM ProviderName: FPL_IndicationProvider. System Firmware detected an error during Fabric Init. Probable Cause: Error detected by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact your HP Support Representative for assistance. WBEM EventID: 6869. WBEM ProviderName: FPL_IndicationProvider. System Firmware detected a failure during Fabric Init. Probable Cause: Failure detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and contact your HP Support Representative for assistance. WBEM EventID: 6870. WBEM ProviderName: FPL_IndicationProvider. System Firmware detected an error during Fabric Optimize. Probable Cause: Error detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events and contact your HP Support Representative for assistance. WBEM EventID: 6871. WBEM ProviderName: FPL_IndicationProvider. Input power to the specified UPS has failed. WBEM EventID: 2963. WBEM ProviderName: FPL_IndicationProvider. Input power to the specified UPS has been restored. WBEM EventID: 2964. WBEM ProviderName: FPL_IndicationProvider. UPS power exhausted. The system is being powered down. WBEM EventID: 2970. WBEM ProviderName: FPL_IndicationProvider. During Machine Check handling, SAL failed to rendezvous all the processors. Probable Cause: System firmware cannot roundup the processors during the machine check handler. Recommended Action: Check for faulty processor, possibly the one(s) that failed to rendezvous. Contact your HP representative for support. WBEM EventID: 6855. WBEM ProviderName: FPL_IndicationProvider. SAL failed to clear the CEC logs during Machine check handling. Probable Cause: System firmware failed to clear the CEC logs. Recommended Action: Check for multiple errors or bad CEC. Contact your HP representative for support. WBEM EventID: 6856. WBEM ProviderName: FPL_IndicationProvider. System FW was unable to access the XBC semaphore. Probable Cause: System FW was unable to access the XBC semaphore. Recommended Action: Collect IPMI events, look for additional errors events, and contact HP support for assistance. WBEM EventID: 6868. WBEM ProviderName: FPL_IndicationProvider. System Firmware detected an error while trying to release the XBC Global Semaphore. Probable Cause: Error detected by SFW while trying to release the XBC Global Semaphore. Recommended Action: Collect IPMI events and contact your HP Support Representative. WBEM EventID: 6872. WBEM ProviderName: FPL_IndicationProvider. Platform Events 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
A write to a Skyline Global LINK_SEL_COHx CSR failed. Data field: cell number of
the Skyline that failed. Probable Cause: System firmware was unable to write a fabric
hardware register. Recommended Action: Capture IPMI event logs, look for additional
errors. Contact your HP Support Representative to analyze the fabric. WBEM EventID:
2960. WBEM ProviderName: FPL_IndicationProvider.
Warning
10439
Unable to write the XBC port scratch CSR with the routing state. Data field: (routing
state) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable
to write a fabric hardware register. Recommended Action: Capture IPMI event logs,
look for additional errors. Contact your HP Support Representative to analyze the
fabric. WBEM EventID: 2962. WBEM ProviderName: FPL_IndicationProvider.
Warning
10475
System Firmware was unable to access the configured set stored in the complex
profile. Probable Cause: SFW was unable to access the configured set stored in the
complex profile. Recommended Action: Collect IPMI events and contact your HP
Support Representative. WBEM EventID: 6874. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10481
System Firmware detected an error during Fabric Init. Probable Cause: Error detected
by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact
your HP Support Representative for assistance. WBEM EventID: 6869. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10482
System Firmware detected a failure during Fabric Init. Probable Cause: Failure
detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and
contact your HP Support Representative for assistance. WBEM EventID: 6870. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10483
System Firmware detected an error during Fabric Optimize. Probable Cause: Error
detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events
and contact your HP Support Representative for assistance. WBEM EventID: 6871.
WBEM ProviderName: FPL_IndicationProvider.
Warning
10487
Input power to the specified UPS has failed. WBEM EventID: 2963. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10489
Input power to the specified UPS has been restored. WBEM EventID: 2964. WBEM
ProviderName: FPL_IndicationProvider.
Warning
10490
UPS power exhausted. The system is being powered down. WBEM EventID: 2970.
WBEM ProviderName: FPL_IndicationProvider.
Error
10495
During Machine Check handling, SAL failed to rendezvous all the processors.
Probable Cause: System firmware cannot roundup the processors during the machine
check handler. Recommended Action: Check for faulty processor, possibly the one(s)
that failed to rendezvous. Contact your HP representative for support. WBEM
EventID: 6855. WBEM ProviderName: FPL_IndicationProvider.
Warning
10509
SAL failed to clear the CEC logs during Machine check handling. Probable Cause:
System firmware failed to clear the CEC logs. Recommended Action: Check for
multiple errors or bad CEC. Contact your HP representative for support. WBEM
EventID: 6856. WBEM ProviderName: FPL_IndicationProvider.
Warning
10510
System FW was unable to access the XBC semaphore. Probable Cause: System FW
was unable to access the XBC semaphore. Recommended Action: Collect IPMI events,
look for additional errors events, and contact HP support for assistance. WBEM
EventID: 6868. WBEM ProviderName: FPL_IndicationProvider.
Warning
10516
System Firmware detected an error while trying to release the XBC Global Semaphore.
Probable Cause: Error detected by SFW while trying to release the XBC Global
Semaphore. Recommended Action: Collect IPMI events and contact your HP Support
Representative. WBEM EventID: 6872. WBEM ProviderName:
FPL_IndicationProvider.
Warning
10518
Platform Events