HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 49

to troubleshoot the Cell Board and/or PDH Daughtercard. WBEM EventID: 714.

Page 49 highlights

Event ID Event Severity 8137 Error 8138 Warning 8139 Warning 8140 Error 8141 Error 8143 Warning 8147 Error 8149 Warning 8151 Warning 8153 Warning Event Description Cell boot has been disabled due to a failure setting the frequency registers. Probable Cause: Invalid data programmed in the Cell's FRU EEPROM or a CPU module's Scratch/FRU EEPROM. Recommended Action: If in manufacturing, program correct data in partition specific field of the Cell or CPU Module's FRU EEPROM. Otherwise, contact HP support personnel to troubleshoot the problem. WBEM EventID: 632. WBEM ProviderName: FPL_IndicationProvider. An error has occurred while updating System FW. Probable Cause: Other error indicated by FWUU. Recommended Action: Exit from FWUU, reset the MP using the XD command, then attempt to update Sytem FW. If repeated attempts to update the System FW fail, contact HP support personnel to troubleshoot the problem. WBEM EventID: 633. WBEM ProviderName: FPL_IndicationProvider. The PDHC firmware was reset for some unknown reason. Probable Cause: A PDHC watchdog timer timeout has occurred because the PDHC was stuck in some unknown state. Recommended Action: Upgrade PDHC firmware to the latest revision. If the error continues, contact HP support personnel to troubleshoot the PDH Daughtercard and/or Cell Board. WBEM EventID: 634. WBEM ProviderName: FPL_IndicationProvider. Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable Cause: A hardware fault exists in the communication path to a CPU module's thermal sensor, or in the thermal sensor itself. Recommended Action: Contact HP support personnel to troubleshoot the Cell Board, the PDH Daughtercard, and/or the offending CPU module. WBEM EventID: 635. WBEM ProviderName: FPL_IndicationProvider. A CPU module has reported overtemp, so will be powered off in 1 minute. Probable Cause: The Processor Information ROM on the processor module is unprogrammed or programmed with invalid temperature thresholds. Recommended Action: Contact HP support personnel to troubleshoot the problem. WBEM EventID: 636. WBEM ProviderName: FPL_IndicationProvider. An error occurred while updating the PDHC firmware. Probable Cause: Other error indicated by Firmware Update. Recommended Action: Exit from Firmware Update, reset the MP using the XD command, then attempt to update PDHC firmware again. If repeated attempts to update the PDHC firmware fail, contact HP support personnel to troubleshoot the problem. WBEM EventID: 637. WBEM ProviderName: FPL_IndicationProvider. Boot is disabled because the cell type does not match the System FW ROM type. Probable Cause: The cell's installed CPU modules do not all have the same type, frequency and partition compatibility, so the Cell type cannot be accurately determined. Recommended Action: Contact HP support personnel to troubleshoot the mismatched CPU module. WBEM EventID: 712. WBEM ProviderName: FPL_IndicationProvider. The PDHC has waited an abnormally long time for PDH bus access. Probable Cause: A hardware fault is preventing the PDH arbiter from granting the PDHC control of the bus. Recommended Action: Contact HP support personnel to troubleshoot the cell board and/or PDH daughtercard. WBEM EventID: 713. WBEM ProviderName: FPL_IndicationProvider. The PDHC has waited an abnormally long time to obtain the PDH semaphore. Probable Cause: A hardware fault is preventing the PDH bus semaphore from being taken/released as expected. Recommended Action: Contact HP support personnel to troubleshoot the Cell Board and/or PDH Daughtercard. WBEM EventID: 714. WBEM ProviderName: FPL_IndicationProvider. An error occurred while transmitting an IPMI message in the BMC2HOST direction. Probable Cause: A hardware fault is preventing the BMC2HOST queue from working. Recommended Action: Contact HP support personnel to troubleshoot the PDH Daughtercard. WBEM EventID: 715. WBEM ProviderName: FPL_IndicationProvider. Platform Events 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Cell boot has been disabled due to a failure setting the frequency registers. Probable
Cause: Invalid data programmed in the Cell's FRU EEPROM or a CPU module's
Scratch/FRU EEPROM. Recommended Action: If in manufacturing, program correct
data in partition specific field of the Cell or CPU Module's FRU EEPROM. Otherwise,
contact HP support personnel to troubleshoot the problem. WBEM EventID: 632.
WBEM ProviderName: FPL_IndicationProvider.
Error
8137
An error has occurred while updating System FW. Probable Cause: Other error
indicated by FWUU. Recommended Action: Exit from FWUU, reset the MP using
the XD command, then attempt to update Sytem FW. If repeated attempts to update
the System FW fail, contact HP support personnel to troubleshoot the problem. WBEM
EventID: 633. WBEM ProviderName: FPL_IndicationProvider.
Warning
8138
The PDHC firmware was reset for some unknown reason. Probable Cause: A PDHC
watchdog timer timeout has occurred because the PDHC was stuck in some unknown
state. Recommended Action: Upgrade PDHC firmware to the latest revision. If the
error continues, contact HP support personnel to troubleshoot the PDH Daughtercard
and/or Cell Board. WBEM EventID: 634. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8139
Cell boot has been disabled because setup of a CPU thermal sensor failed. Probable
Cause: A hardware fault exists in the communication path to a CPU module's thermal
sensor, or in the thermal sensor itself. Recommended Action: Contact HP support
personnel to troubleshoot the Cell Board, the PDH Daughtercard, and/or the offending
CPU module. WBEM EventID: 635. WBEM ProviderName: FPL_IndicationProvider.
Error
8140
A CPU module has reported overtemp, so will be powered off in 1 minute. Probable
Cause: The Processor Information ROM on the processor module is unprogrammed
or programmed with invalid temperature thresholds. Recommended Action: Contact
HP support personnel to troubleshoot the problem. WBEM EventID: 636. WBEM
ProviderName: FPL_IndicationProvider.
Error
8141
An error occurred while updating the PDHC firmware. Probable Cause: Other error
indicated by Firmware Update. Recommended Action: Exit from Firmware Update,
reset the MP using the XD command, then attempt to update PDHC firmware again.
If repeated attempts to update the PDHC firmware fail, contact HP support personnel
to troubleshoot the problem. WBEM EventID: 637. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8143
Boot is disabled because the cell type does not match the System FW ROM type.
Probable Cause: The cell's installed CPU modules do not all have the same type,
frequency and partition compatibility, so the Cell type cannot be accurately
determined. Recommended Action: Contact HP support personnel to troubleshoot
the mismatched CPU module. WBEM EventID: 712. WBEM ProviderName:
FPL_IndicationProvider.
Error
8147
The PDHC has waited an abnormally long time for PDH bus access. Probable Cause:
A hardware fault is preventing the PDH arbiter from granting the PDHC control of
the bus. Recommended Action: Contact HP support personnel to troubleshoot the
cell board and/or PDH daughtercard. WBEM EventID: 713. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8149
The PDHC has waited an abnormally long time to obtain the PDH semaphore.
Probable Cause: A hardware fault is preventing the PDH bus semaphore from being
taken/released as expected. Recommended Action: Contact HP support personnel
to troubleshoot the Cell Board and/or PDH Daughtercard. WBEM EventID: 714.
WBEM ProviderName: FPL_IndicationProvider.
Warning
8151
An error occurred while transmitting an IPMI message in the BMC2HOST direction.
Probable Cause: A hardware fault is preventing the BMC2HOST queue from working.
Recommended Action: Contact HP support personnel to troubleshoot the PDH
Daughtercard. WBEM EventID: 715. WBEM ProviderName: FPL_IndicationProvider.
Warning
8153
Platform Events
49