HP Integrity Superdome SX2000 HP Insight Manager WBEM Provider Events Referenc - Page 8
Event Description, Event, Severity, Event ID
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Event ID Event Severity 754 Error 4 Warning 5 Error 6 Error 755 Warning 756 Error Event Description Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 102. WBEM ProviderName: SEL02_IndicationProvider. A temperature inside the server has gone outside the factory specified range. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. Shutdown the system. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: You should quit applications and shutdown the system.Find cause of temperature anomaly and fix it. WBEM EventID: 103. WBEM ProviderName: SEL02_IndicationProvider. A temperature inside the server has gone far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 104. WBEM ProviderName: SEL02_IndicationProvider. Temperature sensor crossed upper non-recoverable threshold. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 105. WBEM ProviderName: SEL02_IndicationProvider. One of the temperature sensors crossed its upper non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: You should quit applications and shutdown the system.Find cause of temperature anomaly and fix it. WBEM EventID: 107. WBEM ProviderName: SEL02_IndicationProvider. A temperature inside the server went far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 108. WBEM ProviderName: SEL02_IndicationProvider. 8 WBEM Provider Event Tables